Ceramic Fuel Bed Installation - Valor Retrofire RF24IDN Installation And Owner's Manual

Valor retrofire direct vent fireplace insert
Hide thumbs Also See for Retrofire RF24IDN:
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Top Convection Baffl e Installation
Position the fi rebox as far back as possible within the existing
fi replace to allow ample space at front for the fret and to allow
convection air to fl ow under the smoke curtain of the existing fi replace.
Position the top convection baffl e with the threaded studs pointing
downwards into the slots at the top of the fi rebox. Slide the convection
baffl e as far forward as possible, angled down if possible, to force
the air under the smoke curtain, and tighten the wing nuts.
Ceramic Log Set Installation
Carefully remove the ceramic logs from the packaging
taking care not to damage them. Install the logs as
described below.
NG ONLY: Drop Rear Log into place
behind front log retainers.
Front Log locating pins
1
26
Firebox Installation
Wingnuts (2)

Ceramic Fuel Bed Installation

LPG ONLY:
Drop Rear Log into
place centered side-
to-side against back
support so the log
sits more vertical.
Please note that the Rear Log will have a different
position depending of the gas type.
The position of the logs is critical to insure the
good performance of the appliance.
Rear Log Touches
Front Log Here
Place Font Log onto locating
2
Pins at Each End
Start wingnuts on studs. Slide
Convection Baffle into slots.
Adjust Baffle Forward to Touch
Back of Smoke Curtain of
Existing Fireplace. Tighten
Wingnuts.
Right Log
Locating Pins

Advertisement

Table of Contents
loading

This manual is also suitable for:

Retrofire rf24idp

Table of Contents