Replacement of the Fusing Unit
1. Remove the Top Front Cover.
2. Remove the Top Cover.
3. Open the Right-side Door.
4131D032AA
4131D033AA
4. Remove two screws and the Fusing Unit Cover.
5. Unplug the connector from the Power Unit and
remove the harness from the cord holder.
6. Remove the Fusing Unit from the machine (two
screws and two connectors).
7. To reinstall the Fusing Unit, reverse the order of
removal.
8. Select functions as follows: Service -> Service/
Service Person -> Reset Counter/Fuser Unit.
Then, clear the counter.