(10) Removal of the Second Image Transfer Roller Pressure Contact Solenoid
1. Remove the Transport Unit
See page 108
4131D505AA
4131D509AA
2. Remove the Transport Unit gear mounting
bracket.
3. Remove one screw and the 2nd Image Transfer
Roller Pressure Contact Solenoid.