4
Replace PWB-P.
(4)
FATAL ERROR CODE 0CH / SERVICE CALL 0C PWR SUPPLY FAN: Malfunction
of the power supply cooling fan motor
<Remedy>
Power supply cooling fan motor (M4)
Step
Remedy
1
Check M4 operation.
2
Replace PU.
3
Replace PWB-A.
4
Replace PWB-P.
(5)
FATAL ERROR CODE 0EH / SERVICE CALL SUCTION FAN: Malfunction of the
fusing cooling fan motor
<Remedy>
Fusing cooling fan motor (M5)
Step
Remedy
1
Check M5 operation.
2
Replace PU.
3
Replace PWB-A.
4
Replace PWB-P.
(6)
FATAL ERROR CODE 10H / SERVICE CALL LASER UNIT: Malfunction of the
polygon motor
<Remedy>
Electrical components for detection of the malfunction
Print head unit
Step
Remedy
-
Components for display of the warning
Master board (PWB-A)
Power unit (PU)
Controller control board (PWB-P)
Reference
page
Control signal
151
M4_REM
-
-
-
Components for display of the warning
Master board (PWB-A)
Power unit (PU)
Controller control board (PWB-P)
Reference
page
Control signal
151
M5_REM
-
-
-
Master board (PWB-A)
Power unit (PU)
Controller control board (PWB-P)
Reference
page
Control signal
162
-
-
WARNING DIAGRAM
Location(electrical com-
ponent)
3-D
-
-
-
-
-
-
WARNING DIAGRAM
Location(electrical com-
ponent)
11-E
-
-
-
-
-
-
WARNING DIAGRAM
Location(electrical
component)

Hide quick links: