CHAPTER 13 TROUBLESHOOTING
Status 35 (feeding assembly trouble status in detail)
Bit
Meaning
0
Parity bit (odd number)
1
Reserved
2
Reserved
3
Reserved
4
Reserved
5
Reserved
6
Main motor trouble
7
0
[Bit 6]
When the ready signal does not come continuously at 0.1 seconds after the main motor
drive starts, this becomes 1.
When the ready signal is continuous at 0.1 seconds after the main motor drive has
stopped, this becomes 1.
13-134
Table 13-531
COPYRIGHT © 1999 CANON INC.
1
Out of order
CANON GP160 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
0
Normal