Canon GP160DF Service Manual page 324

Hide thumbs Also See for GP160DF:
Table of Contents

Advertisement

CHAPTER 13 TROUBLESHOOTING
#1 SSSW-SW12: Page timer settings
SW
Bit
No.
No.
0
Page time out interval when transmitting (none
when set to image mode)
1
2
Page time out interval when transmitting (when
set to image mode and A4 document mode)
3
12
4
Page time out interval when receiving
5
6
Reserved
Separate transmission and reception page timer
7
settings
These switches can set the page timer. When transmission or reception takes more
than 32 minutes on this machine, communications are stopped. When the timer is set to
other than 32 minutes, refer to the following page and set the appropriate time.
When "do not set" is selected for Bit 7, the one page time out interval is controlled by
Bit 0 and Bit 0, regardless of the communication mode.
13-90
Function
Table 13-512
COPYRIGHT © 1999 CANON INC.
Set
CANON GP160 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Bit setting
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Do not set