Vacon nx User Manual page 75

Frequency converter
Hide thumbs Also See for nx:
Table of Contents

Advertisement

CABLING AND CONNECTIONS
AI1 mode: 0...20mA; Current input
AI1 mode: Voltage input; 0...10V
AI1 mode: Voltage input; 0...10V (differential)
AI1 mode: Voltage input; -10...10V
AO1 mode: 0...20mA; Current output
AO1 mode: Voltage output; 0...10V
Figure 6-32. Jumper selection for OPTA1
!
NOTE
24-hour support +358 (0)201 212 575 • Email: vacon@vacon.com
Ju m p er b lo ck X 1 :
A I1 m o d e
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
Ju m p er b lo ck X 6 :
A O 1 m o d e
A
B
C
D
A
B
C
D
= Factory default
If you change the AI/AO signal content also remember to
change the corresponding board parameter in menu M7.
Ju m p er b lo ck X 2 :
A I2 m o d e
A
B
C
D
AI2 mode: 0...20mA; Current input
A
B
C
D
AI2 mode: Voltage input; 0...10V
A
B
C
D
AI2 mode: Voltage input; 0...10V (differential)
A
B
C
D
AI2 mode: Voltage input; -10...10V
Ju m p er b lo ck X 3 :
CM A a n d CM B g r o u n d in g
CMB connected to GN D
CMA connected to GN D
CMB isolated from GN D
CMA isolated from GN D
CMB and CMA
internally connected together,
isolated from GN D
vacon • 75
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

NxspNxs

Table of Contents