Design and function
TIG welding
5.7.5
Advanced settings
5.7.5.1
Setting the ignition current and upslope time
To change the advanced setting parameters, hold down the "Welding parameters"
button for 2 seconds after selecting the welding process.
The following diagram shows the setting options.
Display
28
Setting/selection
Ignition current
Setting: 1% to 200% of main current AMP (depending on main current)
Upslope time to main current
Setting: 0.0 sec. to 20.0 sec. (factory setting 1.0 sec.)
NOTE
Figure 5-10
099-002003-EW501
19.09.2011