7.3
Dynamic power adjustment
A correctly designed mains fuse is a prerequisite.
•
Observe the details about the mains fuse in the "Technical Data" chapter!
The dynamic power adjustment automatically adjusts the welding performance to an uncritical level for
the fuse.
There are three performance settings for the dynamic power adjustment in the advanced settings
(Parameter FUS): 20 A, 16 A, 10 A.
The currently selected value will be shown on the
machine has been switched on.
ENTER (Enter the menu)
•
Switch off machine at the main switch.
•
Hold down the "Welding process" button and simultaneously switch the machine on again.
Wait until the "Elt" menu item is shown and release the button.
EXIT (Exit the menu)
•
Select the "EIt" menu item.
•
Press the "Welding parameters" button (settings will be applied, machine changes to the
ready-to-operate status).
099-002003-EW501
19.09.2011
0
1
NOTE
section of the display for three seconds after the
NOTE
0
1
Figure 7-2
Rectifying faults
Dynamic power adjustment
35