5.6.4
Antistick
5.6.5
Advanced settings
5.6.5.1
Arcforce correction (welding characteristics)
To change the advanced setting parameters, hold down the "Welding parameters"
button for 2 seconds after selecting the welding process.
The following diagram shows the setting options.
Display
099-002003-EW501
19.09.2011
Setting/selection
Arcforce correction (setting -10 to 10, factory setting 0)
•
Increase value > harder arc
•
Decrease value > softer arc
Design and function
Anti-stick prevents the electrode from annealing.
If the electrode sticks in spite of the Arcforce device, the
machine automatically switches over to the minimum
current within about 1 second to prevent the electrode
from overheating. Check the welding current setting
and correct according to the welding task!
Figure 5-5
NOTE
Figure 5-6
MMA welding
23