3.43 [1-1] Slot—Card Property - EM type
3.43 [1-1] Slot—Card Property - EM type
The properties for the E & M card can be specified.
Interface
Selects E & M signal type.
Value Range
Continuous, Pulsed with Answer, Pulsed without Answer, Continuous No Answer
Maintenance Console Location
3.43 [1-1] Slot—Card Property - EM type
Programming Manual References
None
Feature Guide References
None
First Dial Timer (TIE)
Specifies the minimum time that the PBX waits after seizing a DDI/DID or TIE line, before sending the dialled
digits to the telephone company or to another PBX. This allows the telephone company or the other PBX to
have enough time to accept the dialled digits correctly.
Value Range
32 ´ n (n=1–255) ms
Maintenance Console Location
3.43 [1-1] Slot—Card Property - EM type
Programming Manual References
None
Feature Guide References
None
Answer Detection Timer
Specifies the length of time required by the PBX to recognise the answer signal. This allows the telephone
company to have enough time to accept the dialled digits correctly.
Value Range
32 ´ n (n=1–255) ms
370