Troubleshooting and tips
7.8

Added drive reported as defective

RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
"Hot-plug hard disk drives" on page
I
Further information is provided in the "Integrated RAID for SAS User's
Guide" (on the PRIMERGY ServerView Suite DVD 2 under Industry
Standard Servers - Expansion Cards - Storage Adapters - LSI RAID / SCSI
Controllers) or in the "Modular RAID Controller Installation Guide" (on the
PRIMERGY ServerView Suite DVD 2 under Industry Standard Servers -
Expansion Cards - Storage Adapters - LSI RAID / SCSI Controllers).
For more information on configuring the controller, see section
uring the server" on page
7.9

Error message on screen

The meaning of the error message is explained in the documentation for the
relevant components and programs on the PRIMERGY ServerView Suite
DVD 2.
TX300 S5
Added drive reported as defective
93).
79.
Operating manual
"Config-
89

Advertisement

Table of Contents
loading