Control Panel
RF Repeater Fail – The RF repeater fault registers once the system detects that the wireless
repeater is disconnected, tampered or jammed.
2 RF Low Battery
This fault occurs when any of the RF wireless devices report a low battery condition to the
control panel. While in Fault Analysis Mode, press and hold the [2] key until two beeps sound.
This displays the zone reporting the RF Low Battery fault.
3 Zone Tamper Fail
This fault occurs when any zone with tamper becomes an open circuit. Press and hold the [3]
key until two beeps sound. This displays the zone reporting the tamper fail fault.
4 Sensor Watch Fault
A sensor watch fault registers because one or more detection devices failed to detect any
movement during the disarmed state for the time period programmed by your installer. The
fault clears once the zone in question detects movement and resets. Press and hold the [4]
key until two beeps sound. This displays the zone reporting the sensor watch fault.
5 RF Sensor Watch
An RF sensor watch fault registers because one or more RF detection devices fails to
communicate to the RF radio receiver for the time period programmed by your installer. The
fault clears once the RF device in question successfully transmits to the RF radio receiver.
Press and hold the [5] key until two beeps sound. This displays the RF detection device
reporting the RF sensor watch fault.
6 Communication Fail
A communication fail registers when the control panel fails to communicate with the receiving
party (such as a monitoring company, mobile phone). The communication fault clears once the
control panel successfully reports to the receiving party.
A communication fail also registers when network module is disconnected or tampered.
To determine which receiver or module failed to communicate, press and hold the [6] key.
7 Output and Codepad Fail
The output fault registers when the output expander B308 is disconnected or tampered.
The codepad fault registers when any codepad is tampered or disconnected from the control
panel.
To determine which fault occurred, press and hold the [7] key.
8 Keyfob Low Battery
This fault occurs when any of the RF keyfobs report a low battery condition to the control
panel.
5.7
Date and Time
Programming the date and time is only required when you need functions such as automatic
test reports, automatic arming, and history events to operate correctly.
How to Program the Date and Time
1.
2.
3.
Bosch Security Systems, Inc.
Enter your Master Code, followed by [6] and the [#] key (for example, [25806#]). Three
beeps sound, and the STAY and AWAY indicators flash.
Enter the day, month, year, hour, and minute(DD, MM, YY, HH, MM format) (for example,
DD = day of the month, MM = month of the year, YY = current year, HH = hour of the day,
MM = minute of the day). To program the hour of the day, use the 24:00 hour format.
Press the [#] button to exit and return to the disarmed state. Two beeps sound, and the
STAY and AWAY indicators turn off. If a long beep sounds, an error was made when
entering the date and time.
Operation with ICON LCD Codepad | en
User's Guide
21
2014.05 | 01 | F01U298028
Need help?
Do you have a question about the ICP-SOL2-P and is the answer not in the manual?