Control Panel
3.4

Audible Indications

Below table defines the audible indicators given out by the codepad buzzer.
Audible Indicator
One short beep
Two short beeps
Three short beeps
One long beep
One beep every sec
One short beep every min
One beep every 4 sec.
One beep every 2 sec.
Table 3.1: Audible Indicators
Bosch Security Systems, Inc.
Definition
A button was pressed on the codepad, or Exit Time ended
when armed in STAY Mode 1 or STAY Mode 2.
The system accepted your code.
The requested function was executed.
Indicates the last 10 seconds of Exit Time when armed in AWAY
Mode, or the requested operation was denied or aborted.
Indicates codepad panic/fire/medical alarm operation.
Walk Test Mode is currently active.
There is a system fault waiting to be acknowledged.
During Auto Arming Pre-Alert Time, the warning before
automatic arming takes place.
During Exit Time when armed in AWAY Mode.