PLATINUM Inverter 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
Technical Data
Input characteristics
Max. PV power
Max. DC power
Max. DC voltage
PV voltage range, M P P T
Max. input current
Number of string inputs
Number of MPP trackers
DC disconnect
Reverse battery protection
Output characteristics
Max. AC power
Nominal AC power rating
Nominal AC current
Max. AC current
Feed operation starts at
Mains output voltage range
Mains frequency
Short-circuit proof
Internal consumption at night
Interfaces
DC input
AC output
PLATINUM network
Service interface
Potential-free relay contact
Appliance data
Max. conversion efficiency
European efficiency
Working temperature range
74
Installation and operating manual: PLATINUM Inverter 4300 TL, 4800 TL, 5300 TL, 6300 TL, 7200 TL
Version 05/2010
Mat. No. 734 559-AB
14
Technical Data
4300 TL
4,900 Wp
5,400 Wp
4,300 W
4,800 W
351 – 710 V 348 – 710 V 349 – 710 V 350 – 710 V 351– 710 V
13.0 A
2
Optional DC disconnector, integrated in the appliance
4,120 W
4,600 W
3,750 W
4,200 W
16.3 A
17.9 A
7 W
EIA 485, 2x RJ45 Western Modular add. plug connector with
Change-over contact, maximum 24 V
97.3%
96.8%
4800 TL
5300 TL
6,000 Wp
5,300 W
880 V
14.5 A
16.0 A
2
2
1
yes
5,000 W
4,600 W
18.3 A
20.0 A
20.0 A
21.7 A
7 W
7 W
230 V (+/-20%) single-phased
47,5 Hz – 52,2 Hz
yes
below 2 W
DC-Stecker, Multicontact MC4
Spring clamp connectors
terminal screws
EIA 232, SubD 9-pole socket
/2A, plug connector with
AC
terminal screws
97.4%
97.4%
97.0%
97.0%
-20 °C to +60 °C
6300 TL
7200 TL
7,100 Wp
8,000 Wp
6,300 W
7,200 W
18.5 A
21.0 A
3
3
6,000 W
6,900 W
5,500 W
6,300 W
23.9 A
27.4 A
26.1 A
30.0 A
8 W
8 W
97.7%
98.0%
97.3%
97.6%