Technical Data - Platinum 5500 R3-S2B User And Installation Manual

Table of Contents

Advertisement

Technical data

9
Technical data
Input variables
Max. PV power
Max. DC power (cos ϕ = 1)
MPPT voltage range (MPPT1 / 2)
Max. input voltage (per MPPT)
Max. MPPT input current (MPPT1 / 2)
Number of string inputs (MPPT1 / 2)
Number of MPP trackers
Short circuit current (MPPT1 / 2)
Reverse voltage protection / earth fault monitoring
Output variables
Nominal power (cos ϕ = 1)
Nominal current
Max. apparent power
Max. AC current
Fuse protection on the AC side
Min. start power
Mains voltage
Mains frequency
Feed-in/monitoring phases
Max. network impedance permitted (Z
Standby consumption
Short-circuit strength / earth fault monitoring
(AFI)
Power factor (cos ϕ)
Max. short circuit current (max. duration: 5 ms)
Inrush current
Ground fault monitoring
Efficiency
Max. efficiency
EU efficiency rate
Type name
44
3 AC 230 V / 400 V + N (+/– 20 %)
)
max
Installation and user guide PLATINUM® inverter 5500 R3-S2, 7000 R3-S2, 8000 R3-S2, 9000 R3-S2
5500 R3-S2
5,800 Wp
5,200 W
150 – 720 V / 150 – 720 V
900 V
9,5 A / 9,5 A
1/1
2
14 A / 14 A
Isolation control
5500 R3 -S2
5,000 W
3 x 7.2 A
5,600 VA
3 x 9,9 A
3 x 16 A
20 W
50 Hz (+/– 5 %)
3 feed-in / monitoring phases
1 W
Yes
0.7 ind ... 0.7 cap
120 A
4 A
RCD
5500 R3 -S2
98.5%
98.1%
5500 R3-S2B

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7000 r3-s2b8000 r3-s2b9000 r3-s2b

Table of Contents