Angle Sens.
Along
Angle Sens.
Athw.
3 dB Beamw.
Along
3 dB Beamw.
Athw.
P3402/C
Options:
0.0 to 100.0 in steps of 0.1.
Angle sensitivity in the fore-and-aft direction. Angle
sensitivity of split-beam transducer = electrical angle in
degrees for one mechanical angle in degrees.
Refer to paragraph SPLIT BEAM OPERATION in
section "Theory of Operation".
Options:
0.0 to 100.0 in steps of 0.1.
Angle sensitivity in the athwartships direction. Angle
sensitivity of split-beam transducer = electrical angle in
degrees for one mechanical angle in degrees.
Refer to paragraph SPLIT BEAM OPERATION in
section "Theory of Operation".
Options:
0.0 to 99.9 degrees in steps of 0.1 degree.
3 dB beamwidth of transducer in the fore-and-aft
direction.
Refer to paragraph SPLIT-BEAM OPERATION in
section "Theory of Operation".
Options:
0.0 to 99.9 degrees in steps of 0.1 degree.
3 dB beamwidth of transducer in the athwartships
direction.
Refer to paragraph SPLIT-BEAM OPERATION in
section "Theory of Operation".
Simrad EY 500
45