NEC Univerge SV8100 SL1000 Installation Manual page 28

Mycalls call recorder
Hide thumbs Also See for Univerge SV8100 SL1000:
Table of Contents

Advertisement

In the Sense application, select the tools / options menu and then click the Server tab and scroll down
to the PCI Compliance section. Set the Detect DTMF command option to true, this will enable the
feature. The other options can be set as required, any DTMF digits must be preceeded with a '# 'or a
'*', details of each option are in the table below.
Option
Detect DTMF
commands
DTMF Detection
interval (seconds)
Restart recording
timeout
Start Recording
command (Agent)
Start Recording
command (Customer)
Stop Recording
command (Agent)
Stop Recording
command (Customer)
To save and apply the settings, click OK. The call recording service will need to be restarted to apply
the setting. When the service is restarted, and calls that are being recorded at that time will not be
available for playback.
Function
Set to 'True' to enable the feature or false to disable it.
The number of seconds between dialling the first and last digits to pause
recording. If the DTMF digits are spread over a longer interval, the
sequence will not be detected. The max value is 15 seconds.
Set the maximum duration not to record in seconds. When recording
has been paused it will automatically restart after this timer expires. If
the value is set to 0 then recording will only restart when the start
command is sent again.
This is the DTMF sequence to start recording again after it has been
stopped. Enter # or * and a digit(s) as required, this action is recognised
by a user on the PBX.
This is the DTMF sequence to start recording again after it has been
stopped. Enter # or * and a digit(s) as required, this action is recognised
by the outside caller.
This is the DTMF sequence to stop recording. Enter # or * and a digit(s)
as required, this action is recognised by a user on the PBX.
This is the DTMF sequence to stop recording. Enter # or * and a digit(s)
as required, this action is recognised by the outside caller.