Installation

Connecting The ISDN Call Recorder.

The call recording unit can be rack mounted, free standing or mounted in a CD ROM bay of a PC.
The patch leads connecting through the tap connector should each be no longer than 5 metres in
length. The USB lead supplied with the call recording unit is 1 metre in length. This will mean the call
recording until and PC will have to be situated near each other.
The ISDN lines are connected from the NTE into the tap connector supplied with the call recording
unit. A cable should then run from the other socket on the tap connector to the ISDN card in the PBX.
Once both are connected, calls will be able to pass through the tap connector. There are different
types of tap connectors, one for BRI and one for PRI. The PRI is black and the BRI is white, both are
clearly labelled and can only be used on their respective call recorder.
Once the lines are connected through the tap connector, the other two cables labelled in and out
should be connected to the front of the call recording unit accordingly. Securely connect the supplied
power adapter to the call recording unit and firmly connect the supplied USB lead to the rear of the
call recording unit. Connect the USB lead to the PC until before installing the call recording software.
If the operating system starts the new hardware found wizard, click cancel.