Microlife WatchBP Office Central Instruction Manual
Hide thumbs Also See for WatchBP Office Central:

Advertisement

Quick Links

WatchBP Office Central
WatchBP Office Central
Cardiovascular Screening Solution for:
-Central blood pressure measurement
-Ankle Brachial Index assessment
-Atrial fibrillation detection
-Simultaneous assessment of the Inter-Arm Blood
Pressure Difference
Instruction Manual
1
EN

Advertisement

Table of Contents
loading

Summary of Contents for Microlife WatchBP Office Central

  • Page 1 WatchBP Office Central WatchBP Office Central Cardiovascular Screening Solution for: -Central blood pressure measurement -Ankle Brachial Index assessment -Atrial fibrillation detection -Simultaneous assessment of the Inter-Arm Blood Pressure Difference Instruction Manual...
  • Page 2 1. Cheng, H.M., et al., Measurement Accuracy of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Validation Report for Microlife WatchBP Office Central. Am J Hypertens. 2013. 26: 42-50. 2. Stergiou, G.S., et al., Diagnostic accuracy of a home blood pressure monitor to detect atrial fibrillation. J Hum Hypertens, 2009. 23: 654-8.
  • Page 3: Table Of Contents

    In «CENTRAL» mode ..........27 «SCREEN» mode ...........11–12 In «ABI» mode ............. 28 Appendix Taking measurements using WatchBP Office Central Rechargeable battery and power adaptor ..... 30 «SCREEN» mode ..........13–14 Troubleshooting ............31 Taking less than three measurements ......14 Error messages............
  • Page 4: Product Description

    Product description Name of parts I/O switch Cuff Socket (R) Main Adaptor Socket Battery Compartment Cuff Socket (L) Serial Port ROUTINE AUSCULT. SCREEN Recharge Indicator Display M Button (Memory) Mode Switch Start/Stop Button ABI CENTRAL SCREEN...
  • Page 5 WatchBP Office Central Display Mean Arterial Pressure (MAP) Pulse Pressure (PP) Value for Left Arm Mode Indication Systolic Value External Power Diastolic Value Atrial Fibrillation Detection Central Systolic/ Pulse Pressure Inter-arm Difference L/R Cuff Value for Right Arm Supine Position Reminder...
  • Page 6: Components And Accessories

    Components and accessories AC Adaptor X1 (Input: 100-240V~50/60Hz 0.48A WatchBP Office Central Output: +7.5V 2A) Blood Pressure Device Serial Port Connecting Cable Cuff for upper arm M-L size (22cm~42cm) X 2 Cuff for ankle Instruction Manual M size (22cm~32cm) X 1...
  • Page 7: Before Using Watchbp Office Central

    Two upper arm cuffs and an ankle cuff are provided within the 1) Place the cuff over the left (or right) upper arm so that standard package of the WatchBP Office Central. the air tube and artery mark arrow point towards the lower arm.
  • Page 8: Selective Cuffs For Upper Arm And Ankle

    22 - 32 cm (8.7 - 12.6 inches) 32 - 42 cm (12.6 - 16.5 inches) With air tube 200 cm With air tube 200 cm Please contact Microlife or its distributor to purchase L-XL size or other size cuffs.
  • Page 9: Application Of The Ankle Cuff

    WatchBP Office Central Application of the ankle cuff 3) Wrap and tighten the cuff around the leg. (in ABI mode) 4) Leave a little free space between the leg of the patient 1) The patient has to lie down in supine position.
  • Page 10: Abi» Mode

    Select an operation mode «ABI» mode AUSCULT. SCREEN The WatchBP Office Central device includes three operation Select «ABI» mode for Ankle-Brachial measurement. modes: «ABI», «CENTRAL», and «SCREEN» . Use the Select the arm with the higher blood pressure value as Mode Switch to select the desired mode.
  • Page 11: Central» Mode

    The user can manually set measurement intervals of 15, 30, Automated duplicate measurements 45 or 60 seconds in CENTRAL mode. (Please see “Setting In «CENTRAL» mode, the WatchBP Office Central device measurement intervals” at page 17)) automatically takes two consecutive measurements at 15...
  • Page 12: Screen» Mode

    Three operation modes (cont.) Simultaneous dual-arm measurements «SCREEN» mode In «SCREEN» mode, the WatchBP Office Central device Select «SCREEN» mode to perform fully-automated triple measures the patient’s blood pressure on both arms measurements on both arms. simultaneously, for determining the arm with the highest blood pressure value and revealing the possible presence of peripheral arterial disease.
  • Page 13 WatchBP Office Central Automated triple measurements In «SCREEN» mode, the WatchBP Office Central device automatically takes three consecutive measurements on both arms at fixed one minute* intervals. After the last measurement the average of three blood pressure values is displayed on the LCD screen.
  • Page 14: Screen» Mode

    Taking blood pressure measurements «SCREEN» mode 3) Switch to «SCREEN» mode 1) Turn on the power – Turn on the device by switching the On/Off switch at the back of the device to the ON position. ABI CENTRAL SCREEN ABI CENTRAL SCREEN ABI CENTRAL SCREEN 4) Inflation by fuzzy logic –...
  • Page 15: Taking Less Than Three Measurements

    WatchBP Office Central Taking less than three measurements 6) Three consecutive measurements – The device will take three consecutive measurements with one minute The measurement procedure can be stopped at anytime intervals between measurements. by pressing the Start/Stop button in «SCREEN» mode.
  • Page 16: Central» Mode

    Taking blood pressure measurements (cont.) «CENTRAL» mode 3) Switch to «CENTRAL» mode. 1) Turn on the power – Turn on the device by switching the On/Off switch at the back of the device to the ON position. ABI CENTRAL SCREEN ABI CENTRAL SCREEN ABI CENTR 2) Apply the cuff –...
  • Page 17 WatchBP Office Central 5) Press the <<M>> to switch between left(L) and right(R). 7) Automatic two measurements – The device will Press the Start/Stop button to confirm. take two consecutive measurements with 15 second intervals in between on default. 15 seconds switch 8) Inflation by fuzzy logic –...
  • Page 18: Skipping The Countdown Time

    Taking blood pressure measurements (cont.) Skipping the countdown time Setting measurement intervals in «CENTRAL» mode The countdown time before measurement in «SCREEN» mode and «CENTRAL» mode can be skipped by pressing 1) Press and hold the Start/Stop button for 3 seconds. the Start/Stop button.
  • Page 19: Abi» Mode

    WatchBP Office Central «ABI» mode 1) Turn on the power – Turn on the device by switching 4) Apply the cuff* – Properly fit the arm cuff to the upper the On/Off switch at the back of the device to the ON arm and the ankle cuff to the leg of the preferred position.
  • Page 20 Taking blood pressure measurements (cont.) 6) Start the measurement – Press the Start/Stop button 8) Display of the measurement values– to start the measurement. The measurement values will be displayed and the Ankle-brachial index is automatically calculated when the measurement is completed. The Ankle-brachial index and the blood pressure value display first, the brachial index value is replaced by the pulse value for 3 seconds.
  • Page 21: Special Functions

    Am J Hypertens, 2012. 25: 542-8. 2. Cheng, H.M., et al., Measurement accuracy of a stand-alone oscillometric central blood pressure monitor: a validation report for Microlife WatchBP Office Central. Am J Hypertens, 2013. 26: 42-50.
  • Page 22: Mean Arterial Pressure And Pulse Pressure

    Pulse Pressure (PP) Mean Arterial Pressure (MAP) This measurement device provides the pulse pressure (PP) The WatchBP Office Central device measures the true mean arterial pressure (MAP). Each measurement includes a of the patient: pulse pressure = systolic - diastolic pressure.
  • Page 23: Appearance Of The Atrial Fibrillation Indicator

    This device detects atrial fibrillation, a major cause of stroke. Wiesel J, et al. Detection of atrial fibrillation using a modified Microlife Not all risk factors for stroke, including atrial flutter, may be blood pressure monitor.
  • Page 24: About Atrial Fibrillation

    Special Function (cont.) About atrial fibrillation Determine the proper arm and inter-arm difference Atrial fibrillation is a common heart rhythm problem. It affects more than 2 million people in North America. If the blood pressure difference between two arms is more It is more common in older age and it is found in 18% than 20mmHg for Systolic or 10mmHg for Diastolic at all three individuals aged 85 years and older.
  • Page 25: Abi (Ankle Brachial Index)

    WatchBP Office Central ABI (Ankle Brachial Index) A low ankle-brachial index (ABI) is indicative of systemic vascular disease, and places a patient in the high-risk The systolic blood pressure values of a person’s arm and category. leg need to be measured In order to determine ABI (Ankle Brachial Index).
  • Page 26: Hiding Measurement Values

    1) Activate the «Hide» Function – Press <<M>> button; L or R flashes; keep pressing and hold the <<M>> button The WatchBP Office Central features a Hide function in order for 7 more seconds until On or Off flashes. to prevent unnecessary elevated blood pressure in patients...
  • Page 27: Viewing And Transferring Measurement Data

    Viewing and transferring measurement data WatchBP Office Central «SCREEN» mode 1) Viewing the average of all measurements When the last measurement is performed in «SCREEN» seconds... mode, press the <<M>> button to display the average of three measurements. 3) Viewing individual measurements – All individual readings can be viewed by repeatedly pressing the <<M>>...
  • Page 28: In «Central» Mode

    Viewing and transferring measurement data (cont.) «CENTRAL» mode 3) Viewing individual measurements – All individual readings can be viewed by repeatedly pressing the 1) Viewing the average of all measurements <<M>> button. The display will show a number before When the last measurement is performed in «CENTRAL» the reading to indicate the measurement sequence.
  • Page 29: In «Abi» Mode

    WatchBP Office Central «ABI» mode 3) Viewing MAP and PP values – Ten seconds after display of the average blood pressure 1) When the last measurement is performed in «ABI» mode, value, the values for Pulse Pressure (PP) and Mean press the <<M>>...
  • Page 30 Viewing and transferring measurement data (cont.) Transferring measurement data Transferring data to the computer Installation of the software program 1) Start the software program and connect the device to the computer using the cable supplied. 1) Put the CD in the CD-ROM drive of your computer or click on «...
  • Page 31: Rechargeable Battery And Power Adaptor

    WatchBP Office Central Software commands Refer to the software user manual for detailed information and instructions. Perform a measurement Click «Measure» Stop a measurement Click «Stop» Store data Click «Save» Close Click «Close» Please read the software manual to know more details of the software operation commands.
  • Page 32: Appendix

    Rechargeable Battery Using a power adaptor The device is equipped with a built-in, rechargeable Ni-MH Please only use the Microlife adaptor supplied with the device to recharge the device. battery pack which delivers up to 400~500 measurement cycles. The batteries can be recharged while the power 1) Plug the adapter cable into the Power Plug of the adaptor is plugged in.
  • Page 33: Troubleshooting

    Make sure the tube of the cuff is securely connected to the device. Leakage of the tube or Check for cracks on the tube or the bladder. Please contact bladder Microlife customer service for this issue. No result displayed between The Hide function is activated Disable “hide” function measurements...
  • Page 34: Error Messages

    Repeat the measurement, keeping your arm still. Please contact your local Microlife service center if the error persists. If you think the results are unusual, please read through the information in this instruction manual carefully.
  • Page 35 Error messages WatchBP Office Central Err 11 Signal too weak The pulse signals on the cuff Err 3 No pressure in An adequate pressure during Central are too weak. Re-position the cuff cannot be generated in blood pressure the cuff and repeat the the cuff.
  • Page 36 Err 13 Cuff pressure An adequate pressure Pulse or cuff The pressure in the cuff is too errors during cannot be generated in pressure too high (over 300 mmHg) OR Central blood the cuff. A leak may have high the pulse is too high (over pressure occurred.
  • Page 37: Safety And Protection

    Safety, care, accuracy test and disposal WatchBP Office Central Read the instruction manual carefully before using this device, especially the safety instructions, and keep the instruction manual for future use. Observe the storage and operating conditions described in Safety and protection the “Technical specifications”...
  • Page 38: Accuracy Test

    Do not wash the cuff! Do not iron the cuff! Accuracy test Disposal We recommend the WatchBP Office Central device be Batteries and electronic instruments must tested for accuracy every 2 years or after mechanical be disposed of in accordance with the locally impact (e.g.
  • Page 39: Technical Specifications

    Static accuracy: pressure within ± 3 mmHg • Pulse accuracy: ±5 % of the readout value • Voltage source: Rechargeable battery pack; 4.8V C3500 mAh • Mains adapter DC 7.5V, 2 A Microlife reserves the right to alter technical specifications without prior written notice.
  • Page 40: Guarantee Card

    Address: from the date of purchase. This guarantee is valid only on presentation of the guarantee Date: card completed by the owner confirming date of purchase or purchase receipt. Telephone: E-mail: Product: WatchBP Office Central Product Number: TWIN200 CBP Date:...
  • Page 41 Tel +41 71 727 7000 Tel +886 2 8797 1288 Tel +1 303 274 2277 Fax +41 71 727 7011 Fax+886 2 8797 1283 Fax +1 303 274 2244 Email: watchbp@mimhs.com Email: watchbp@microlife.ch Email: watchbp@microlife.com.tw www.watchbp.com www.watchbp.com www.watchbp.com IB WatchBP Office Central EN 2713...