INSTALLATION
Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
non-combustible board.
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the
paint may discolour.
Combustible mantel leg clearances as per diagram:
12
MANTEL CLEARANCES
12
10
30
20
30"
10
0
To Unit
Base Legs
MANTEL LEG CLEARANCES
MANTEL LEG
Allowable mantel
leg projection
8
6
4
2
13" (330mm)
3 ½" (89mm)
1" (25mm)
21"
Standoff
20"
Top of
Fireplace
28-1/8"
Opening
4"(102mm)
Non-Combustible
1.5" (38mm)
5-1/2" (140mm)
8" (203mm)
11" (279mm)
Combustible Material
Drywall
Metal Stud
(On Edge)
Non-combustible
Facing
Regency Horizon HZ54EPV Gas Fireplace