Optional Fan Wiring Diagram - Regency Fireplace Products HZ54EPV-NG Owners & Installation Manual

Horizon series hz54epv gas fireplace
Table of Contents

Advertisement

INSTALLATION
Lockwasher
Star washer
(for mobile home)
Nut
Fan
ground wire
Electrical Connection Alternative Scheme "A",
Power at Stove
Wall Junction Box
~
Wire Nuts
14 AWG wire
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by stove fan only)
Copper Ground
120 Volts
White (Neutral)
60 Hz
Black (Hot)
14 AWG wire
32

OPTIONAL FAN WIRING DIAGRAM

WITHOUT PROFLAME GTMF SYSTEM
#8 Ground Lug
*Speed Control
Switch with
lead wires
(Regency)
120 Volts
60 Hz Copper Ground
Wire Nuts
* = supplied with fan kit
Other parts are to be supplied
by electrician or installer
Green (Ground)
120 VAC
White (Neutral)
60HZ
Black (Live)
(*by others)
(*by others)
Rotary Speed
Control
ON
OFF
Black
Electrical Connection Alternative Scheme "B",
Power at Switch
Wall Junction Box
~
Black (Hot)
White (Neutral)
Wire
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
Fan
White
Thermodisc
*Speed Control
Switch with lead wires
Wire Nuts
Black
White
14 AWG wire
Ground
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by unit fan only)
Regency Horizon HZ54EPV Gas Fireplace
Ground for
mobile home
Fan
(*Supplied
by others
- install
according to
local code)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hz54epv-lp

Table of Contents