installation
Mantel Clearances
Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in
the diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with
a non-combustible board. The non-
combustible mantel when installed at
a lower overall height may not be lower
than 6 inches from the top of the fireplace
opening.
Note: Ensure the paint that is used on the
mantel and the facing is "High Quality"
or the paint may discolour.
Mantel Leg Clearances
Combustible mantel leg clearances as per diagram:
18
Regency Horizon ® HZ54E-11 Gas Fireplace
|
12
10
14
30
20
30"
10
0
To Unit
Base Legs
MANTEL LEG
Allowable mantel
leg projection
8
6
4
2
13" (330mm)
3 ½" (89mm)
Drywall
1" (25mm)
Metal Stud
(On Edge)
21"
20"
Top of
Fireplace
28-1/8"
Opening
4"(102mm)
Non-Combustible
1.5" (38mm)
5-1/2" (140mm)
8" (203mm)
11" (279mm)
Combustible Material
Non-combustible facing.
Must be supported
using steel stud or
the framing kit