This is a copy of the label that accompanies
each HZ54EPV-NG and HZ54EPV-LP Direct
Vent Gas Fireplace. We have printed a copy of
the contents here for your review.
®
NOTE: Regency
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
Listed:
Certified for/Certifi e pour:
Tested to:
4001172
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
NATURAL GAS: Model HZ54EPV-NG
Min. Supply Pressure
5" WC
Low Setting Man. Pressure
1.6"WC
Max. Manifold Pressure
3.5"WC
Orifice Size
#30DMS
Minimum Input
29,000Btu/h
Maximum Input
41,500 Btu/h (12.16 kW)
Altitude
PROPANE GAS: Model HZ54EPV-LP
Min. Supply Pressure
12"WC
Low Setting Man. Pressure
Max. Manifold Pressure
Orifice Size
Minimum Input
Maximum Input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. Listed for use with Power Vent Kit #946-705.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si ces normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational
Vehicles. Homologué avec terminaison à évacuation mécanique 946-705.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si
les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements.
This vented gas fireplace heater is not for use with air filters.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY
Electrical supply / Électrique 115VAC, 2.5 A, 60Hz.
.
NOT FOR USE WITH SOLID FUEL. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Regency Horizon HZ54EPV Gas Fireplace
VENTED GAS FIREPLACE HEATER /
é
CANADA and U.S.A.
CAN/CGA-2.17-M91,ANSI Z21.88a-2007/CSA 2.33a-2007
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR CET POELE: Mod le
(1.25 kpa)
Pression d'allimentation minimum
(0.40 kpa)
Pression à la tubulure d' chappement lev e
(0.87 kpa)
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
(8.50 kW)
D bit
é
Calorifique
D bit
é
Calorifique
0-4500 ft/pi (0-1372 m)
l'altitude
É
QUIP A L'USINE POUR GAZ PROPANE
É
CONCU POUR CET POELE: Mod le HZ54EPV-LP
(2.98 kpa)
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
6.4"WC
(1.59 kpa)
Pression à la tubulure d' chappement basse
10"WC
(2.49 kpa)
Grandeur de l'injecteur
#49 DMS
30,000Btu/
(8.79 kW)
D bit
é
Calorifique
D bit
é
Calorifique
37,000Btu/h (10.84 kW)
l'altitude
0-4500 ft/pi (0-1372 m)
Duplicate S/N
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
FOYER AU GAZ À ÉVACUATION
é
HZ54EPV-NG
é
é
é
é
minimum selon
maximum selon
é
é
é
é
é
minimum selon
maximum selon
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL

SAFETY LABEL

373
Serial No./ No de serie
373
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Side Walls
A
B
D
Ceiling
F
B
Min. Mantel Height
A
C
C
Max. Mantel Depth
D
Alcove Width
E
E
Alcove Depth
F
DOOR SEAL: Please
check that the door is
properly sealed
(See Instruction Manual for
detailed instructions)
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada/ Fabrique au Canada
4" (102mm)
40-7/8" (1038mm)
20" (508mm)
13" (330mm)
83" (2108mm)
36" (914mm)
918-940