Combustible Mantel Clearances; Minimum Clearances To Combustibles - Regency Fireplace Products FPI E33 Owners & Installation Manual

Gas insert natural gas/propane
Table of Contents

Advertisement

INSTALLATION
From Unit
* A 8" (203 mm)
Side Walls
B 47" (1194 mm)
Ceiling
Min. Mantel Height C 15" (381 mm)
D 12" (305 mm)
Max. Mantel Depth
E 76" (1930 mm)
Alcove Width
36" (914 mm)
Alcove Depth
F
G 1-1/4" (32 mm)
Hearth Height
H 45-1/2" (1156 mm)
Hearth Width
13" (330 mm)
Hearth Depth
I
* Alcove side wall must have a min. of 8"
clearance on one side.
10

MINIMUM CLEARANCES TO COMBUSTIBLES

COMBUSTIBLE MANTEL CLEARANCES

Because of the extreme heat this fi replace emits, the mantel clear-
ances are critical.
Note: A non-combustible mantel may be installed at a lower height
if the framing is made of metal studs covered with a non-
combustible board.
Mantel can be installed anywhere in shaded area or higher using the
above scale.
Note: Ensure the paint that is used on the mantel and the facing
is "heat resistant" or the paint may discolour.
E33 FPI Direct Vent Gas Insert