Real Flame Hot Box Installation & Operating Manual page 17

Real flame hot box gas firebox installation & operating manual
Hide thumbs Also See for Hot Box:
Table of Contents

Advertisement

OPTIONAL POWER FLUE
(continued)
Installation Instructions
(continued)
HORIZONTAL FLUE RUN
The maximum length of horizontal flue run is to be 13.5 metres with a maximum of four (4)
bends; these bends can be 45° or 90°. The horizontal flue run is to have a grade downwards
from the motor to the termination.
VERTICAL FLUE RUN
The minimum vertical flue run is 900mm from the top of the firebox (1500mm from the floor). If a
longer vertical run is required twin skin flue 150mm & 200mm can be added between the muffler
top and the fan. The flue can be cut to the required height.
FLUE CLEARANCES
All flue clearances are as per the requirements listed in the heater specifications.
TERMINATION
The termination to be used for all horizontal installations is to be 150mm cowl that has been
approved as a horizontal cowl.
Installation of Power Flue Kit
POWER FLUE MUFFLER
The power flue muffler has a spigot at each end. The end that attaches to the firebox has a
spigot equivalent to the inner flue spigot diameter of the firebox, the top of the muffler has a
150mm spigot which the motor fits to, or the 150/200 twin skin flue if required. The flow arrow
on the muffler is to be pointing up.
WIRING (see wiring diagram page 22)
A 3 metre lead is supplied with the power flue, this lead has a different connection on each end,
one end is plugged into the connection on the left hand side of the firebox and the other end is
to be plugged into the fan. The wire coming from the rear of the firebox with the standard 3-pin
plug attached is to be plugged into a power point. A single gang wall switch is also supplied
attached to the 3 metres of lead; this wall switch is to be attached at a location accessible to the
client. No other wiring is required.
SERVICING OF THE POWER FLUE MOTOR
The Real Flame Power Flue motor is designed so as to make servicing the motor a simple task.
The power lead connected to the motor is to be disconnected (unplugged) and the two side clips
are to be undone, the fan motor will then lift out for servicing. The fan Motor box connected to
the flue does not have to be disconnected from the flue.