MAGIGLO
®
SERIES
INSTALLATION & OPERATING MANUAL
The Magiglo series of decorative fires are suitable to be installed into a
masonry or approved prefabricated fireplace and are designed to operate
with Natural and Propane gases only. Approval Number GMK10098.
VERSION 20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Magiglo Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Real Flame Magiglo Series

  • Page 1 ® SERIES INSTALLATION & OPERATING MANUAL The Magiglo series of decorative fires are suitable to be installed into a masonry or approved prefabricated fireplace and are designed to operate with Natural and Propane gases only. Approval Number GMK10098. VERSION 20...
  • Page 2: Warranty Information

    (www.realflame.com.au) or completing and mailing the attached registration card within 30 days of purchase of your Real Flame Gas Burner (or, if the Real Flame Gas Burner is fitted to a new home, within 30 days of the date of settlement of purchase of such new home).
  • Page 3: Ventilation Requirements

    INSTALLATION NOTICE The installation of this appliance is only to be carried out by an authorised person in accordance with the Manufacturer’s Instructions, local gas fitting regulations, AS/NZS5601.1-2013 installation code for gas burning appliances and any other relevant statutory regulations. In all cases the installation of this appliance shall meet the requirements as set out in AS/NZS5601.1-2013 NOTE: A slight smell may be apparent for the first few hours of use.
  • Page 4: Table Of Contents

    Typical Type 1 Installation to existing chimney ............14 Type 1 Installation into Victorian/Federation grate ..........15 Typical Type 2 Installation of Prefabricated Fire Box into existing chimney ..16 User Instructions....................17 Troubleshooting ....................17 Conversion details ....................18 Parts List.......................19 Real Flame contact information................20...
  • Page 5: Data Plate

    (Affixed to the base of the unit for reference to gas pressure & consumption) DATA PLATE BURNER MODEL NATURAL GAS ULPG INJ. SIZE MJ/Hr TPP (kPa) INJ. SIZE MJ/Hr TPP (kPa) 2.40 0.80 1.20 2.60 2.50 0.80 1.30 2.70 2.60 0.80 1.30 2.70...
  • Page 6: Dimensions

    DIMENSIONS Magiglo 320 Burner PLAN FRONT Magiglo 360 PLAN FRONT...
  • Page 7 DIMENSIONS Magiglo 400 Burner PLAN FRONT Magiglo 540 PLAN FRONT...
  • Page 8 DIMENSIONS Magiglo 750 PLAN FRONT...
  • Page 9 DIMENSIONS Magiglo 1000 PLAN 1029 FRONT Magiglo 540 Double Vision Burner PLAN FRONT...
  • Page 10: Installation Instructions

    BURNER INST LL TION Select the Magiglo series burner which best compliments your fireplace size. Locate your gas fire into the rear of the fireplace or prefabricated fire box fixing to base or grate by location lugs on burner.
  • Page 11: Lighting Instructions

    FOR YOUR SAFETY READ BEFORE LIGHTING The appliance has a pilot which must be lit using the piezo ignition, when lighting the pilot follow the instructions exactly. Before lighting the appliance check for gas leaks. Use only your hand to push in and turn the gas control knob, never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician.
  • Page 12 LIGHTING INSTRUCTIONS - Magiglo 400, 540 & 750 To light the pilot, press in and turn the gas control knob anticlockwise to the pilot position. (Fig 1) Fig 1 Depress the knob and press the red button. If the pilot lights, continue to depress knob for 20 seconds and release.
  • Page 13: Commissioning Procedure

    COMMISSIONING PROCEDURE Once the fire is installed and operational the installer must check for spillage. Carry out the lighting procedure and turn the fire to high. Allow to warm up for 10 minutes and then using a smoke match set 25mm down and 25mm inside of the fire opening run the match across the width of the opening to check that all of the smoke is drawn away.
  • Page 14: Typical Type 1 Installation To Existing Chimney

    TYPICAL TYPE 1 INSTALLATION TO EXISTING CHIMNEY Optional For Type 1 installations models with an ODS pilot must be used. 225mm DIA GAS COWL Smoke match spillage test. Ensure gas log fire is set back into fire place in order that no waste products come into the room.
  • Page 15: Type 1 Installation Into Victorian/Federation Grate

    TYPE 1 INSTALLATION INTO VICTORIAN/FEDERATION GRATE EDWARDIAN/VICTORIAN GRATE AIR TUBES COALS CERAMIC BLANKET BURNER PORT CUT OUT SECTION CONTROL BASE GRATE FRONT IRON COAL PLACEMENT Place Air Tubes 5mm behind Burner Port and space evenly. (cut to size if too long). AIR TUBES BURNER 5mm GAP...
  • Page 16: Typical Type 2 Installation Of Prefabricated Fire Box Into Existing Chimney

    TYPICAL TYPE 2 INSTALLATION OF PREFABRICATED FIRE BOX INTO EXISTING CHIMNEY FOR INSTALLATION OF FIRE BOX REFER TO MANUFACTURER’S SPECIFICATIONS. SEAL FLANGE TO BRICKWORK O O F 225mm Dia Gas Cowl Existing Chimney Flue to the required size if chimney does not draw properly Seal flange to brickwork Gather Convection Box...
  • Page 17: User Instructions

    As with all gas appliances, your Magiglo should be regularly serviced. We would recommend once each year. The name and address of your service technician can be obtained from your Real Flame stockist. The routine to be followed by the engineer can be found under Service Instructions; contained within this leaflet.
  • Page 18: Conversion Details

    CONVERSION DETAILS N TUR L G S TO PROP NE Turn appliance off. Turn gas supply off. Remove regulator cap and adjustment nut. Remove regulator spring and replace with correct gas type spring. Replace regulator cap. Remove pilot assembly cover. Remove from valve, oxy pilot thermocouple.
  • Page 19: Parts List

    PARTS LIST PART No. DESCRIPTION PART No. 1/2˝ to 3/8˝ Hex Nipple BM733 Control Valve, Eurosit 630 Valve 5/16˝ 90O Union Elbow Regulator SC-75 S.I.T. ODS Pilot Assembly (Natural Gas) 1/4˝ Nut and Olive Injector Holder Stem S.I.T. ODS Pilot Assembly (Propane Gas) Injector 1/2˝...
  • Page 20: Real Flame Contact Information

    GLEN DIMPLEX AUSTRALIA PTY LTD ABN 69 118 275 460 Head Office/Factory/Showroom 1340 Ferntree Gully Rd. Scoresby Vic 3179 Ph: (03) 8706 2000 Fax: (03) 8706 2001 E-mail: info@realflame.com.au Richmond - VIC Showroom 300 Swan St. Richmond Vic 3121 Ph: (03) 9428 4443 Fax: (03) 9428 4445 Dandenong - VIC Showroom 3/328 South Gippsland Highway, Dandenong South Vic 3164...