Built-In Installation Dimensions

(non-combustible enclosure)
WARNING
Do not install this grill on or near combustible materials.
Doing so can result in death or fire.
IMPORTANT: If grill is to be installed in a combustible enclosure,
return this unit and replace it with the model which is
manufactured for use in a combustible enclosure.
Enclosure and clearance dimensions that are shown must be
used. Given dimensions provide required clearances.
The installation of this grill must conform with the current
standards CSA-Z21.58a-1998, or with local codes.
For installations in a non-combustible enclosure, the grill drops
into the opening and is supported by its side fl anges. Do not use
a bottom support.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
"
12
(30.5 cm)
minimum to
any accessory
"
2
(5.1 cm)
10-7/8
minimum to
(27.0 cm)
open hood
(2.9 cm)
Center or support
surfaces must be level
Non-combustible enclosure installations
Grill size
27" (68.6 cm)
26" (66.7 cm)
36" (91.4 cm)
35" (89.5 cm)
6
Fire Hazard
"
22
A
(57.2 cm)
"
2-1/4
Gas line
(5.7 cm)
location at
rear of grill
"
7-3/8
(18.7 cm)
"
B
optional custom
"
1-1/8
access doors
"
19
(48.3 cm)
A
25-1/4" (64.1 cm)
34-1/4" (87.0 cm)
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualifi ed electrician determine that the
ground path is adequate.
Check with a qualifi ed electrician if you are not sure whether the
grill is properly grounded.
Do not ground to a gas pipe.
A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is
required.
Recommended ground method
"
6
(15.2 cm)
A grounded 3-prong outdoor outlet grounded in accordance with
min. clearance
the National Electrical Code ANSI/NFPA 70 or Canadian Electrical
for rotisserie
Code (C22.1) — and local codes and ordinances.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
"
35-1/2
(90.2 cm)
3-prong polarized ground-
type outdoor outlet
3-prong ground
power supply
cord
B

Electrical Requirements

Built-in models - rotisserie and grill light
WARNING
Electrical Shock Hazard
plug
ground
prong