Pulse Width Modulated (Pwm) Valve - Toro Multi Pro 5700-D Service Manual

Turf sprayer
Hide thumbs Also See for Multi Pro 5700-D:
Table of Contents

Advertisement

Pulse Width Modulated (PWM) Valve

1. Spray pump assembly
2. Flange nut
3. Flange head screw
4. Rear guard plate
5. Flange nut (3 used)
6. Front guard plate
7. Hydraulic hose (PWM to motor)
The Pulse Width Modulated (PWM) Valve is used on the
Multi Pro 5700–D to control gear pump flow to the spray
pump hydraulic motor. Electrical current to the PWM
Valve solenoid coil affects the internal spool setting of
the Valve and thus the hydraulic flow to the spray pump
motor. Component parts for the PWM Valve are not
available.
For information on PWM Valve solenoid testing, see
Pulse Width Modulated (PWM) Valve Solenoid in the
Component Testing section of Chapter 5 – Electrical
System.
Hydraulic System
1
3
2
20
8. O–ring
9. Hydraulic fitting
10. O–ring
11. Cap screw (2 used)
12. PWM Valve
13. Hydraulic hose (from gear pump)
14. Hydraulic tee fitting
12
11
10
5
4
9
7
6
5
19
7
17
Figure 42
IMPORTANT: Correct operation of the PWM Valve
depends on precise assembly and adjustment. No
disassembly or adjustment of the PWM Valve is rec-
ommended.
Page 4 – 46
8
9
13
15
14
10
16
17
8
18
15. Hydraulic hose (to oil cooler)
16. O–ring
17. Hydraulic hose (motor to PWM tee)
18. Flat washer (2 used)
19. Hydraulic motor
20. Pump mount bracket
Multi Pro 5700–D