Log Assembly
1. Remove glass door by removing two (2) screws behind upper grills
and lifting door off bottom door retainer.
2. Remove logs from carton (4) and inspect.
3. Rear log should be installed onto rear log holder attached to back of
firebox above and to the rear of the burner pan.
4. Front log should be centered on the log supports between the front
and rear burners. Push log against the back of the supports.
5. Top logs can then be placed across the front and back logs in the
slots provided.
6. Purge lines and test pilot operation.
7. Spread supplied rocks evenly on front burner, being careful not to
get rock in the crossover tube opening below the front log. Next,
tear ember wool into small, thin, irregular pieces and place it evenly
over rocks.
8. Replace glass door. The door must be installed before operating the
fireplace.
Automatic On/Off Thermostat Controlled
Fan Kit (Part # ZIFK)
1. Open the lower front access cover.
2. Remove the two (2) sensor mounting screws located to the right of
the control valve in the access area on the bottom side of the fire
box. Secure the sensor unit under the fire box being sure to tighten
the screws so the sensor is in contact with the fire box bottom.
3. Insert the two (2) #8x1/2 screws provided with the fan into the
holes in the side of the fireplace opposite the gas line entry. Mount
the fan using the keyhole slots in the fan body.
4. Install a junction box (type to except three prong plug) on the inside
wall of the access area opposite the fan. Large holes are provided to
allow wiring to enter the access area on the left of the unit. Connect
the power, sensor and variable speed wall switch as shown in the
wiring diagram.
Note: If the fan has been installed on the left of the unit it will be
necessary to lengthen the sensor unit leads to reach the sensor.
Install as per diagram.
5. Close lower access cover.
6. Turn the wall switch on (clockwise). Turn the fireplace on. Once the
sensor unit reaches operating temperature in approximately 10 to 15
minutes the fall will turn on. The fan can be switched off, if desired,
by turning the wall switch fully counter-clockwise.
7. To set the minimum fan speed if desired. Remove the variable speed
switch from the wall mount. Turn the variable speed wall controller
to its minimum setting (fully clockwise). Use the set screw on the
side of the variable speed controller to increase or decrease the min-
imum fan speed. (It may be desirable to lower minimum fan speed
to decrease the sound level created by the fan.) Reinstall switch into
wall mount and cover with face plate.
Caution: Should this fan require servicing, the power supply must be disconnected.
Log Assembly & Fan Kit

Fan Kit Installation

Recommended Maximum Lead Length
(Double Wire) When Using Wall Switch or
Thermostat
Electrical Services
All optional fan kits are equipped with a 120V, 60Hz blower.
Note: All electric connections are to be made in accordance with CSA
Standard C22.1 - Canadian Electrical Code part I or with the National
Electrical Code, ANSI/NFPA 70 (latest addition) and/or in accordance
with local codes.
7
Wire Size
Max. Length
14 GA.
100 FT.
16 GA.
18 GA.
20 GA.
22 GA.
64 FT.
40 FT.
25 FT.
16 FT.