Locating Your Appliance; Framing For Your Gas Fireplace - Kingsman “Zero Clearance” ZDV1001 Installation Instructions Manual

Zero clearance direct vent gas fireplace
Table of Contents

Advertisement

(above or below grade)
Installing with Top Vent Option
Island installation with a top vent is possible as long as the horizontal por-
tion of the vent system does not exceed 10 feet (305cm). When you install
your fireplace as in position 'B', 'D' or 'E', a minimum of 6 inches
(153mm) clearance must be maintained from the perpendicular wall and
the front of the appliance.
Framing Specifications
1. Choose fireplace location and frame in accordance with the fire-
place dimensions specified on page one of this manual. When using
a wide 3.5 in. surround the fireplace must be 1/2" (13mm) ahead of
the wall. Also allowances must be made for drywall tile or any other
facing used around the unit. When using Slim Line Brass surround
or no surround fireplace face maybe built out from the framing
specification using non combustible materials such as brick or
stone, giving a reset appearance.
2. Place fireplace into position and secure to floor with 1 1/2" screws
or nails. Nailing tab located left and right lower side of fireplace.
3. Cold climate installation recommendation: when installing this fire-
place against non-insulated exterior wall or chase, it is recommend-
ed that the outer walls be insulated to conform to applicable insula-
tion codes. Drywall should be installed around the unit to prevent
insulation from contacting the body.
4. Drywall can extend flush with the appliance on the bottom and sides
of the fireplace. A non-combustible material must be used to extend
flush with the top of the fireplace and must have a vertical length
equivalent to the height of the standoffs.
5. If you are installing the top vent unit with a 90˚ bend, the minimum
clearance to combustibles directly above the 90˚ bend is 4"
(102mm).
6. Non-combustible materials such as brick and tile can be extended
across the face of the fireplace. If wide 3.5" brass trim kit is going
to be installed, brick and tile will have to be installed flush with the
front of this appliance. If slim line brass trim kit is used, brick or
tile may extend past the front of unit.

Locating your Appliance

Framing for your Gas Fireplace

4
(above grade)
Installing with Back Vent Option
A - Flat on a wall
B - Across the corner
C - As an island
Hearth
A hearth is not mandatory but is recommended for aesthetic purposes.
We recommend a non-combustible hearth projecting out 12" (305mm)
or more in front of the fireplace.
Clearance to Combustibles
Back (from Standoffs)
Side (from standoffs)
Floor
Top (from standoffs)
Top (from front of unit)
Top of 90 Bend
Top of Horizontal Pipe
Note: See Mantel Chart
D - As a room divider
E - Flat on wall corner
F - Exterior wall
0 inches/0 mm
0 inches/0 mm
0 inches/0 mm
0 inches/0 mm
2.5 inches/64 mm
4 inches/102 mm
2.5 inches/64 mm