Installation Instructions ZDV3318 Model Numbers: ZDV3318N, ZDV3318NE, ZDV3318NE2, ZDV3318LP, ZDV3318LPE, ZDV3318LPE2 Certified to: ANSI Z21.88-2017 • CSA 2.33-2017 Vented Gas Fireplace Heaters, CSA 2.17-2017 This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
Table of Contents Table of Contents..............................Pre-installation Questions and Answers / Operations and Maintenance Instructions..........Safety Screen Installation............................Warnings, Installations and Operations - Installation Regulations................Installation Requirements for the Commonwealth of Massachusetts / Carbon Monoxide (CO) Detector....Mobile Home/Manufactured Housing Installation....................Recommendations for Finishing of Clean View Linear Products................
Page 3
Z47ST24 / Z47ST36 Horizontal Snorkel Terminations................... Venting Straight Up Through Roof………………………………………………………………………………………... 50-51 Vertical Venting over 15 Feet..........................Glass Safety / Termination Cap Safety........................Approved for Power Vent PVH58 / PVH58FM......................Parts Lists PVH58 Parts List……………………………………………………………………………………………………………. ZDV3318 Parts List..............................56-57 Troubleshooting Troubleshooting the Gas Control System.......................
Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
Safety Screen Installation Z Series Contents of Kit: [1] Safety Screen [2] Side Angles [2] Horizontal Angles [12-16] DT Screws (Depending on screen size) Assembly: Attach components with supplied screws as shown. NOTE: Screens are symmetrical from top to bottom. ⚠...
Warnings, Installations and Operations - Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
Recommendations for Finishing of Clean View Linear Products When finishing the wall around the fireplace, it is critical that the wall covering be fastened properly. It is acceptable to pre-drill holes and use self-tapping screws which may be used to fasten a backer for tile, marble, etc. Screws being installed through non-combustible board should be self-tapping type with a maximum length of 2 inches.
Intertek safety certification will not apply to this installation method. This installation method must be deemed acceptable by the Authority Having Jurisdiction (AHJ) prior to the indoor gas fireplace being installed. Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected from direct water impingement.
ZDV3318 - Locating your Appliance Installing with Top Vent A - Flat on a wall D - As a room divider B - Across the corner E - Flat on wall corner C - As an island F - Exterior wall Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
ZDV3318 - Framing for your Gas Fireplace 4. When installing horizontal with a 90 degree bend maintain a minimum Framing Specifications of two and a half (2.5”) inches above the bend in enclosures. 1. Cold climate installation recommendation: When installing this fire- 5.
How To Install Clean View Kit (CVCK) For ZDV3318 / ZDV3622 / ZDVRB3622 / ZDV6000 / ZDV3320 / MQRB3328 / MQZDV3318 / MQZDV3622 WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
CLEARANCES - ZDV3318/3622/3622RB - Mantels & Surrounds Warning: Combustible objects must not be placed on a non-combustible mantel unless the non-combustible mantel meets the minimum height and width require ments for a combustible mantel.
Mantel Leg Clearances Mantels Depending on the depth of the fireplace mantel, it may be installed higher or lower from the top of the fireplace opening. See drawings for proper installation height of your combustible mantel. Non-combustible mantels may be installed at any height above the fireplace opening except when using MQHBSW.
Top of Horizontal Pipe 1 1/2 inches/38 mm / All Vent Systems Side & Bottom of Horizontal Pipe 1 inch/25.5mm / All Vent Systems Vertical Vent Pipe 1 inch/25.5mm / Kingsman Vent Systems Vertical Vent Pipe 1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk Direct Temp...
Fan Kit Installation Wire Junction Box and wall mounted variable speed control to Fan installation Instructions for ZDV6000 / 3320 /3318 120v. Install a duplex outlet to junction box and plug fan into /3318MQ / 3622 / 3622RB with or without CVCK (Clean View outlet.
Split Receptacle- Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
Z3318 / Z3622PRL & Z3318ML / Z3622ML Installation Guide Make note of the position of the air adjustment plate before removing it. This position will have to be recalled when the air adjustment plate is reinstalled. Remove three [3] mounting screws from air adjustment plate and extract it from the firebox. (NOTE: The false bottom will have to be removed on models ZDV3318, ZDV3622 and ZDVRB3622.) Remove the [1] Liner Retaining Screw from each side of the firebox.
LOGC50 Log Assembly LOG #1 LOG #5 LOG #2 LOG #6 WARNING: Failure to position the LOG #3 LOG #7 parts in accordance with these diagrams LOG #4 or failure to use only parts specifically approved with this appliance may result in ROCK property damage or personal injury.
Page 22
Log Assembly (continued) STEP 8 - Break glowing ember insulation into STEP 9 - On Log #5, you will find a location slot 1/4” pieces. Place embers onto front burner but that will align with the middle grate bar. Slide ensure you do not cover air slot that is located into place and rest Log #5 onto Log #2’s flat between front burner and false bottom...
3318 / 3622 Door and Glass Information Glass Cleaning Removal of the Glass Door - It will be necessary to clean the glass periodically. During start- ZDV3622,ZDVRB3622, & MQZDV3622: up, condensation, which is normal, forms on the inside of the 1.
1/2 PSIG (3.5 KPa). Note: The gas line connection may be made of 1/2” rigid pipe or an approved Kingsman flex connector, such as FP15GC. Since some municipalities have additional local codes, it is always best to consult your local authorities and the current CAN/CGA - B149.1 or .2 installation code in Canada or the National Fuel Gas code ANSI Z223.1 in the U.S.A.
Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When ...
Annual Inspection List for Determining Safe Operation of a Direct Vent Gas Fireplace Refer to this checklist for proper maintenance, safe use, and operation. See each section for more specific information. 1. Inspect and operate all pressure relief mechanisms (i.e., relief dampers, spring loaded door latches) installed on your appliance to verify relief mechanisms are free from obstruction to operate.
Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
Conversion Kit Instructions – PART A Models: ZDV3318N, ZDV3318NE, ZDV3318NE2, ZDV3318LP, ZDV3318LPE, ZDV3318LPE2 Burner Orifice Kit Number Description Pilot Orifice Brass Nipple Air Shutter Hi/Lo Regulator Brass (1000-255) Propane 3318 -CKLP 1000-P201VE 9/32” 1001-P167SI 1001-P202SI Conversion 3622 -CKLP 1000-P201VE 3/8” #30 (977.167) (0.907.202) -Millivolt-...
Page 29
Gas Conversion –Part A ZDV3318 WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instruction s and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to PROPANE and from PROPANE to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions.
IPI Electronic Ignition System Overview CPI / IPI The IPI system is an advanced burner controller that Switch provides you with the option of having either a Standing- Cover Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
Proflame 1 -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart *thermostatic control of the appliance. *In the U.S.A *thermostats are not permitted for Vented Decorative Gas Fireplaces (ANSI Z21.50). Transmitter Remote Receiver Transmitter...
Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
Proflame 2 IFC Module and Remote Control LCD Display ON / OFF Key Thermostat Key Batteries UP / DOWN Arrow Key Mode Key IFC Module Button Within 10 seconds press the button again until Pairing Remote Control: you hear it beep. ...
Cold Climates – CPI Setting - Proflame 2 Remote Control Use the CPI setting during cold weather, otherwise the fireplace may have a hard time starting up and establishing a flame. The CPI (Continuous Pilot Ignition) setting will keep the firebox and fireplace exhaust vent warm during cold weather. When the firebox and exhaust vent are warm, exhaust gasses will readily flow out of the firebox.
Page 44
Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Note: This function is only available in Room Thermostat or Smart Thermostat Control Mode.
Vent Terminal Clearances Clearances are to the edge of the terminal plate. Add 6-3/4” to clearances to arrive at centerline. Local codes or regulations may require different clearances. WARNING: A HORIZONTAL VENT CERTIFIED GUARD (SAFETY CAGE) IS AVAILABLE WHEN REQUIRED BY LOCAL CODES. Canadian installations US installations Clearance above grade, veranda,...
General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Simpson-Duravent Direct Vent system (Model DV-GS Series), Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
How To Use The Horizontal Vent Table Venting Routes And Components Since it is very important that the vent system maintain its bal- 1. Determine the height of the system and the number of bends ance between the combustion air intake and the flue gas required.
Z47ST24 / Z47ST36 Horizontal Snorkel Terminations Two snorkel terminations are available if a vertical rise is necessary on the exterior side of a building: Z47ST24 (24” Tall, 14-1/2” Center to Center) Z47ST36 (36” Tall, 26-1/2” Center to Center) Follow standard horizontal venting installation procedures. If the Snorkel Termination is to be located below grade, a window well is recommended with adequate and proper drainage as per local codes.
Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney. When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1"...
Page 51
-Restrictor- Remove for Runs Under 15 Feet Clearances in horizontal venting. FDVVT40 Clearance to perpendicular wall 24 inches (60 cm). (Recommended to prevent re- circulation of exhaust products. For additional requirements check local codes.) 24” 18” MIN Clearance above highest point of exit on roof 18 inches (45cm) 43ft...
Vertical Venting over 15 Feet The Air Intake plate must be adjusted down to the lowest position when venting over 15 ft. vertical. 15ʼ OR OVER VERTICAL VENTING AIR INTAKE ADJUSTMENT PLATE NOTE: Unit comes preset for short horizontal or vertical venting under a 15 feet run. Follow these instructions when venting exceeds 15 foot run.
-Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
Approved for Power Vent PVH58 / PVH58FM - This appliance is approved for use with a Kingsman PVH58 Horizontal Power Vent - A Horizontal Power Vent Termination is intended for use where standard venting configurations are not possible. NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are NOT permitted.
PVH58 POWER VENT PARTS LIST NUMBER DESCRIPTION PVH58 Horizontal Power Vent Termination Power Vent Control Module – Millivolt Box PVC58MV Power Vent Control Module – IPI Box PVC58IPI Main Wiring Harness Assembly – Extension Harness (20ft) PVH20H 4/7 VENTING AND VENTING ADAPTERS For fireplaces to be converted to hard pipe (Duravent-DirectVent Pro, etc.) at the fireplace: Duravent Fireplace Adapter (ZRB46 Only) ZDVDKA...
Troubleshooting the Gas Control System ⚠ WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is...
During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.