Kingsman ZV6500 Installation Instructions Manual

Zero clearance vented gas fireplace

Advertisement

Installation Instructions

Certified to: ANSI Z21.50a-1992, Can1-2.19-M81, CGA, CAN/CGA 2.17-1991
Vented Gas Fireplace
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
Do not store or use gasoline or other flammable vapors and liquids in the
Immediately call your gas supplier from a neighbour's phone.
If you can not reach your gas supplier, call the fire department.
Warning: Improper installation, alteration, service or maintenance can cause property damage, personal
injury or loss of life. Refer to this manual. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Listed Certified for USA. and Canada
Model Number ZV6500
Stock #'s: ZV6500N, ZV6500LP
"Zero Clearance"

FOR YOUR SAFETY

vicinity of this or any other appliance.
What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph: (204) 632-1962
Printed in Canada 03/04/07 Part # 6500-P903CP

Advertisement

Table of Contents
loading

Summary of Contents for Kingsman ZV6500

  • Page 1: Installation Instructions

    Installation Instructions Listed Certified for USA. and Canada Certified to: ANSI Z21.50a-1992, Can1-2.19-M81, CGA, CAN/CGA 2.17-1991 Model Number ZV6500 Stock #’s: ZV6500N, ZV6500LP “Zero Clearance” Vented Gas Fireplace Read this complete manual before beginning installation. These instructions must be kept with the unit for future reference.
  • Page 2 PRE-INSTALLATION QUESTIONS and ANSWERS Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This is due to the curing of the paint, adhesives, silicones and any undetected oil from the manufacturing process as well as the finishing materials used with the installations (e.g.
  • Page 3: Table Of Contents

    Kingsman Fireplace accessories ..... .11 Kingsman Fireplace options ......11 Trouble shooting the gas control system .
  • Page 4: Installation And Operation

    Installation and Operation Installation Regulations 5. Installation and any repairs to this appliance should be done by a qualified service person. A professional service person should be This gas appliance must be installed by a qualified installer in accor- called to inspect this appliance annually. Make it a practice to have dance with local building codes, or in the absence of local codes, with all your gas appliances checked annually.
  • Page 5: Locating Your Appliance

    Locating your Appliance (above or below grade) Installing with Top Vent When you install your fireplace as in position ‘B’, ‘D’ or ‘E’, a minimum A - Flat on a wall D - As a room divider of 6 inches (153mm) clearance must be maintained from the perpendicu- B - Across the corner E - Flat on wall corner lar wall and the front of the appliance.
  • Page 6: Gas Line Installation

    Mantles Depending on the width of the fireplace mantle, it may be installed higher or lower from the top of the fireplace opening. See drawing and chart below for proper installation height of your combustible mantel- piece. Non-combustible mantles may be installed at any height above the fireplace opening.
  • Page 7: Operating And Maintenance Instructions

    Operating and Maintenance Instructions This gas appliance should be installed by a qualified installer in accor- Do not alter gas orifice. dance with local building codes and with current CAN/CGA - B149 (.1 Periodically remove the logs from the grate assembly and vacuum any or .2) installation codes for Gas Burning Appliances and Equipment.
  • Page 8: Log Assembly

    Log Assembly Log Assembly 1. Remove logs from carton (4) and inspect. 2. Rear log should be installed onto rear log holder attached to back of firebox above and to the rear of the burner pan. 3. Front log should be placed and centred on log supports in front of burner.
  • Page 9: Millivolt System, Lighting, & Burner Control

    Millivolt System, Lighting, & Burner Control Lighting Instructions Pilot Burner Adjustment 1. Open access grill on bottom. 1. Remove pilot adjust- 2. Push in gas control knob slightly and turn clockwise to “OFF”. ment cap. NOTE: Knob cannot be turned from “PILOT” to “OFF” unless knob is 2.
  • Page 10: Venting Instruction

    Vent Instructions NOTE: A chimney venting this fireplace shall not vent any other When installing with “B” Vent liquid fuel gas chimney install as per appliance. “B” Vent Manufacturer Installation specifications. Offset vertical or vertical installations may be installed. This appliance may be vented into various types of applications “A” Vent of solid fuel wood burning chimney, Masonry Clay lining and “B”...
  • Page 11: Repair Parts List

    Product Number Description Log Set (Required for Each Unit) Natural Gas Valve System (Robert Shaw) LOGC65 Log Set - 4 pce. Cast Oak (ZDV3620,ZV6500 Series) 1000 - 205R Valve Millivolt NG (711-701-417) Grill Kit: (Required for Each Unit) 1000 - 207R...
  • Page 12: Trouble Shooting The Gas Control System

    Trouble Shooting The Gas Control System WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. Problem Possible Causes Corrective Action Spark igniter will not light.
  • Page 13: Kingsman Industries Gas Fireplace - Limited Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.