Short code
G1ER
IRER
LDTC
LDTE
MAER
PAER
PFTC
PFTE
PSER
PTTC
PTTE
R1ER
SLER
TIER
TSER
UEEF
UEZF
UITC
UITE
YEER
ZFTC
ZFTE
ZOER
The fixture reports a calibration error if valid calibration data is not detected in EEPROM. The fixture may be
unable to read/write calibration data to EEPROM.
32
Long message and explanation
GOBO W 1 ERR
Error in magnetic indexing circuit. Rotating gobo wheel position timeout has been reached.
IRIS ERROR
Error in electric indexing circuit. Iris position timeout has been reached.
LED TEMP CUTOFF
LED board temperature sensor continuously measures temperature above maximum limit.
LED TEMP SEN ERR
LED board temperature sensor error or no communication with sensor.
MAGENTA ERROR
Error in electric indexing circuit. Magenta position timeout has been reached.
PAN ERROR
Pan position electrical indexing system timeout.
PFC TEMP CUTOFF
Power factor correction system sensor continuously measures temperature above maximum
limit.
PFC TEMP SEN ERR
Power factor correction system temperature sensor error or no communication with sensor.
PAN SENSOR ERROR
Fixture unable to retrieve reliable data from pan position sensor.
PT TEMP CUTOFF
Pan/tilt PCB sensor continuously measures temperature above maximum limit.
PT TEMP SEN ERR
Pan/tilt PCB sensor error or no communication with sensor.
GOBO W 1 ROT ERR
Error in magnetic indexing circuit. Rotating gobo position timeout has been reached.
SAFETY LOOP
Safety loop circuit activated. A temperature circuit breaker has shut down LEDs. Circuit breaker
resets automatically after temperature has returned to normal operating range.
TILT ERROR
Tilt position electrical indexing circuit timeout.
TILT SENSOR ERR
Fixture unable to retrieve reliable data from tilt position sensor.
UPL ERR EFFECT
Upload to Pan/Tilt error
UPL ERR Z/F
Upload to Zoom/Focus error
UI TEMP CUTOFF
User interface (display/control panel) sensor continuously measures temperature above
maximum limit.
UI TEMP SEN ERR
User interface (display/control panel) sensor error or no communication with sensor
YELLOW ERROR
Error in electric indexing circuit. Yellow position timeout has been reached.
ZF TEMP CUTOFF
Zoom/focus sensor continuously measures temperature above maximum limit.
ZF TEMP SEN ERR
Zoom/focus sensor error or no communication with sensor.
ZOOM ERROR
Error in electric indexing circuit. Zoom position timeout has been reached.
Table 5: Error messages