Martin MAC Quantum Profile Safety And Installation Manual

Martin MAC Quantum Profile Safety And Installation Manual

475 w long-life led engine
Hide thumbs Also See for MAC Quantum Profile:

Advertisement

MAC Quantum Profile™
SAFETY AND INSTALLATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Martin MAC Quantum Profile

  • Page 1 MAC Quantum Profile™ SAFETY AND INSTALLATION MANUAL...
  • Page 2 The Martin logo, the Martin name, the Harman name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries.
  • Page 3: Table Of Contents

    Contents Safety Information ............4 Introduction .
  • Page 4: Safety Information

    Follow the safety precautions and observe all warnings in this manual, in the MAC Quantum Profile User Guide, and printed on the fixture. The latest versions of this Safety and Installation Manual and the MAC Quantum Profile User Guide are available for download from the MAC Quantum Profile Product Support page on the Martin™...
  • Page 5 • Use only a Neutrik PowerCon NAC3FCA cable connector to connect to the power input socket. • Do not expose the fixture to rain or moisture. • Refer any service operation not described in this manual or in the MAC Quantum Profile User Guide to Martin™ Service or an authorized Martin™ Service partner.
  • Page 6: Introduction

    Release the tilt lock and allow the fixture to cool before packing it in its flightcase. The anti-shock material in the MAC Quantum Profile flightcase is designed to protect the head without the tilt lock applied. Release the tilt lock when transporting the fixture in the flightcase. Leaving the tilt lock applied may cause damage that is not covered by the product warranty.
  • Page 7: Physical Installation

    Warning! The MAC Quantum Profile has a powerful pan motor. The torque reaction when the head is panned suddenly can cause the base to move if the fixture is standing unsecured on a surface. Do not apply power to the MAC Quantum Profile unless the base is securely fastened to a surface or to rigging hardware.
  • Page 8 7. Check that there is no possibility of heads or yokes colliding with other fixtures. 8. Check that other lighting fixtures cannot project intense light at the MAC Quantum Profile, as intense illumination can damage the MAC Quantum Profile’s display.
  • Page 9: Ac Power

    AC power at 120-240 V (nominal), 50/60 Hz. Power input Important! Connect the MAC Quantum Profile directly to AC power. Do not connect it to a dimmer system; doing so may damage the fixture. The MAC Quantum Profile requires a power input cable with a Neutrik PowerCon NAC3FCA cable connector for AC mains power input.
  • Page 10 A, otherwise you may cause arcing at connector Figure 7: Mains input socket and mains power on/off switch terminals that can damage them. MAC Quantum Profile Safety and Installation Manual...
  • Page 11: Dmx Data Link

    1. Connect the DMX data output from the controller to the MAC Quantum Profile’s data input (male XLR) socket. 2. Run the data link from the MAC Quantum Profile’s data output (female XLR) socket to the data input of the next fixture.
  • Page 12: Service And Maintenance

    (including opening the base of the fixture) that is not described in this manual or in the fixture’s User Guide must be referred to Martin™, its approved service agents, or trained and qualified personnel using the official Martin™ service documentation for the MAC Quantum Profile.
  • Page 13: Replacing The Head Air Filters

    Air filters for the MAC Quantum Profile are disposable items that must be replaced, not cleaned. New filters are available from Martin™ suppliers by ordering P/N 50400765 ‘Head air filter, MAC Quantum Profile, set of 12’.
  • Page 14: Servicing Optical Components

    2. Place the product on a suitable work surface. 3. See Figure 9. Position the head so that the Martin logo on the back of the head is facing the right way up and apply the tilt lock (see Figure 1 on page 6).
  • Page 15 The use of metal gobos in the MAC Quantum Profile is not recommended. Do not use gobos with dark coatings on any side, as these will absorb heat –...
  • Page 16 6. Check that the gobo rotates correctly. Figure 13: Removing a rotating gobo 7. When service work is finished, reinstall the multi-module (if you removed it) and the top head cover as described above. MAC Quantum Profile Safety and Installation Manual...
  • Page 17 Replacing the static gobo wheel To replace the static gobo wheel: 1. Remove the top head cover and remove the multi-module as described above. 2. See Figure 14. Remove the three Torx 10 retaining screws (arrowed) from the iris unit. Figure 14: Releasing the iris unit 3.
  • Page 18 C. The alignment pins ensure that the gobo wheel can only be mounted in the correct position and facing in the correct direction. Figure 17: Static gobo wheel alignment 6. When service work is finished, reinstall the multi-module and top head cover as described above. MAC Quantum Profile Safety and Installation Manual...
  • Page 19 Replacing the prism 1. Remove the top head cover as described above. Figure 18: Removing the prism drivebelt 2. See Figure 18. Lift the prism drivebelt off its pulleys. Do not stretch the drivebelt any more than necessary. Figure 19: Removing the rotating prism 3.
  • Page 20: Lubrication

    Figure 20: Correct prism location Color wheel service Color wheel replacement must be carried out by an authorized Martin™ Service agent with Martin™ service documentation. Lubrication The MAC Quantum Profile does not require lubrication under normal circumstances. Moving parts can be checked and a long-lasting teflon-based grease reapplied by a Martin™...
  • Page 21: Using The Fixture

    Using the fixture Before using the fixture, download and read the latest version of the MAC Quantum Profile User Guide from the MAC Quantum Profile Product Support page on the Martin website at www.martin.com. The User Guide contains details of: •...
  • Page 22: Troubleshooting

    Repair or replace damaged cables. Insert DMX termination plug in data output socket Data link not terminated. of the last MAC Quantum Profile on the data link. Fixtures reset correctly but respond erratically or not at all Incorrect addressing of fixtures.
  • Page 23: Specifications

    Fixture software update ......Direct with USB memory stick or over DMX link ......with Martin™ USB Duo DMX Interface Box Optics Light source .
  • Page 24 MAC Quantum Profile™ in 2-unit flightcase ........
  • Page 25 Martin products. This product contains a lithium battery that must be replaced by an authorized Martin™ service agent only. Ensure that it is disposed of correctly and responsibly by an authorized recycling or waste disposal center at the end of its life.
  • Page 28 • Olof Palmes Allé 18 • 8200 Aarhus N • Denmark Tel: +45 8740 0000 • Fax +45 8740 0010...

Table of Contents