• Errors are shown in the display regardless of display status: they override an inactive display and any
other information that the display might be showing.
• If an error is present, the status LED flashes red.
The possible error messages are listed in Table 5
Short code
Long message and explanation
BEAM SHAPER POS
BEER
Error in magnetic indexing circuit. Beam shaper position timeout reached.
BEAM TMP CUT OFF
BETC
Beam temperature sensor continuously measures temperature above maximum limit.
BEAM TMP SEN ERR
BETE
Beam temperature sensor error or no communication with sensor.
COLORWHEEL 1 ERR
C1ER
Error in magnetic indexing circuit. Color wheel position timeout reached.
COM ERR EFFECT
CEEF
Effects module communication error.
COM ERR P/T
CEPT
Pan/tilt system communication error.
COM ERR Z/F
CEZF
Zoom/focus system communication error.
COM ERR LED DRV
CELD
LED driver communication error or no communication with sensor.
FIXTURE COLD
COLD
Fixture too cold. Physical movement of effects is disabled until fixture has warmed up.
CYAN ERROR
CYER
Error in electric indexing circuit. Cyan position timeout has been reached.
DC TEMP CUT OFF
DCTC
DC PCB temperature sensor continuously measures temperature above maximum limit.
DC TEMP SEN ERR
DCTE
DC PCB temperature sensor error or no communication with sensor.
EFF TEMP CUT OFF
EFTC
DC PCB temperature sensor continuously measures temperature above maximum limit.
EFF TEMP SEN ERR
EFTE
DC PCB temperature sensor error or no communication with sensor.
BASE 1 FAN ERR
FAN
Base fan 1 error or no communication with sensor.
BASE 2 FAN ERR
FAN
Base fan 2 error or no communication with sensor.
BASE 3 FAN ERR
FAN
Base fan 3 error or no communication with sensor.
HEAD FAN 1 ERR
FAN
Base fan 1 error or no communication with sensor.
HEAD FAN 2 ERR
FAN
Head fan 2 error or no communication with sensor.
HEAD FAN 3 ERR
FAN
Head fan 3 error or no communication with sensor.
HEAD FAN 4 ERR
FAN
Head fan 4 error or no communication with sensor.
PAN FBACK ERR
FBEP
Pan position magnetic indexing system timeout. Fixture is unable to correct pan position (but
pan movement will often still be possible).
TILT FBACK ERR
FBET
Tilt position magnetic indexing system timeout. Fixture is unable to correct tilt position (but tilt
movement will often still be possible).
FIX GOBO W 1 ERR
FG1E
Error in magnetic indexing circuit. Static gobo wheel position timeout has been reached.
FOCUS ERROR
FOER
Error in electric indexing circuit. Focus position timeout has been reached.
:
Table 5: Error messages