Other Station Equipment

SLT Adapter — P/N 0891026
Door Box — P/N 92245
110-Button DSS Console — P/Ns 0890051 & 0890052
24-Button DLS Console — P/Ns 0890053 & 0890054
10
The SLT Adapter converts a digital port from an ESIU PCB into
an analog port which can be used for connecting on-premise
2500 type single line devices (i.e., telephones, fax machines,
modems, etc.) and to telco OL13B/C OPX circuits. The SLT
Adapter provides the ring generator circuit used by the analog
device. The unit provides constant current which is fixed at 47
mA. Each SLT Adapter requires its own digital port.
Refer to Single Line Telephones in the Software Manual for more details.
The Door Box is a self-contained Intercom unit typically used to monitor an
entrance door. A visitor at the door can press the Door Box call button (like a
door bell). The Door Box then sends chime tones to all extensions programmed
to receive chimes. A 2PGDAD Module is required for this feature.
Each 2PGDAD module audio output can optionally support two analog Door
Boxes. In addition, you can connect each circuit's control relay to an electric door strike. This
allows an extension user to remotely activate the door strike while talking to a visitor at the Door
Box. The control relays are normally open. The NTCPU also provides 1 relay. This relay is defined
as relay '0' in programming. The relays on the 2PGDAD modules are numbered 1-8. The system
can have up to eight Door Boxes.
The DSS (Direct Station Selection) Console gives a keyset user a
Busy Lamp Field (BLF) and one-button access to extensions,
trunks and system features. The 110-Button DSS Console pro-
vides an additional 100 programmable keys, while the 24-Button
DLS Console provides 24 programmable keys. The 110-Button
DSS also has 10 fixed feature keys for Paging, calling Door Boxes,
activating Night Service and enabling DSS Console Alternate
Answer. There are also two keys that allow "shifting" between the
first and second set of 100 extensions.
Keep the following in mind when installing DSS Consoles:
A 110-Button DSS Console requires a separate digital station port.
Product Description