Safety
Please read this entire manual before installation
and use of this wood burning insert. Failure to follow
these instructions could result in property damage,
bodily injury or even death.
We strongly recommend that smoke detectors be installed. If
smoke detectors have been previously installed, you may notice
that they are operating more frequently. This may be due to curing
of stove paint or fumes caused by accidentally leaving the fi re
door open. Do not disconnect the detectors. If necessary, relocate
them to reduce their sensitivity.
SAFETY NOTICE: If this stove is not properly installed, a
house fi re may result. For your safety, follow the installation
directions. Consult local building or fi re officials about
restrictions and installation inspection requirements in
your area.
Fig. # 1
W a
e n t
j a c
A d
©PACIFIC ENERGY FIREPLACE
8
PRODUCTS LTD.
300mm
l l
51mm
Clearances
Masonry or Factory Built Fireplace
The minimum required clearances to surrounding combustible
materials when installed into a masonry or factory built fi replace
are listed below and in fi gure #1.
Minimum Clearances to Combustibles
(Measured From Insert Door and Decorative Top)
Adjacent Sidewall ....................300mm.
Mantel ......................................600mm.
Top Facing ...............................600mm.
Side Facing ............................. 300mm.
CAUTION: Unit hot while in operation. Parts of the appliance,
especially the external surfaces, will be hot to touch when
in operation. Keep children, clothing and furniture away.
Contact may cause skins burns.
Mantel or Top Facing
600mm
Fireplace
Hearth
300mm
ALT5.ASCINSB 150714-24