be removed from the smoke shelf and adjacent damper frame if
necessary to accommodate a chimney liner, provided that their
removal will not weaken the structure of the fi replace and chimney,
and will not reduce protection for combustible materials to less
than that required by the National Building Code.
The Insert must be installed in accordance with local and or
national building codes. The two methods of fl ue connection
that are acceptable in most areas are:
Full Flue Liner: (Fig.2) where a stainless steel rigid or fl exible
liner extends from the Insert fl ue collar to the top of the chimney.
For difficult installations, this insert is approved for use with
a SPND.3OFFSETA - 3" fl ue offset box. Only this offset box
is approved for use with this insert. The use of any other
offset box may cause a hazard and/ or void any warranty.

Full Flue Liner (Fig #2)

This fi replace insert must be installed with a continuous liner of
150mm diameter extending from the fi replace insert to the top
of the chimney.
Consult your local Dealer about relining your fi replace chimney.
1) Measure the chimney height from the top of the existing fl ue
to the fl oor of the hearth. This will allow extra length of liner
for fl ashing and rain cap.
2) Feed the stainless steel liner from the top of the chimney,
through the damper area and into the fi replace cavity.
3) Attach a stove connector to the bottom of the liner, as per the
instructions provided with the chimney liner.
4) To mount optional rear leveling leg bolts, prop unit up to access
threaded inserts under rear of unit. Thread supplied bolts into
inserts, set depth to correspond to depth of fi replace drop.
5) Push the Insert into position inside the fi replace and attach
the connector to the stove collar and secure with screws.
Use the rear adjusting legs to level the Insert.
Note: To access the holes for securing connector to the stove
collar, remove the top front casing. To remove, undo the screws
located on both sides of the top front(Fig #3) then pull casing
toward you and up. Reverse these steps to install casing top.
If it is necessary to get access to the connector pipe through
the fl ue outlet of the Insert, the baffle can be removed (see
Baffle Removal section).
6) Measure, trim and shape a top fl ashing to fi t the existing
chimney fl ue. Plan for a 25mm to 38mm overlap on each
side. Place fl ashing over top of the liner and seat fi rmly
against the tile.
7) Screw fl ashing collar to liner. Caulk gap around fl ashing with
RTV silicone.
8) Attach a rain cap to the end of the liner. A storm collar should
be used. (Follow vent manufacturers instructions.)

Combustion Air

Consult local building codes regarding combustion air supply.
Intake or combustion air can be supplied to the Insert in one of
©PACIFIC ENERGY FIREPLACE
12
PRODUCTS LTD.
Fig. # 2
Full Flue Liner
Rain Cap
Stainless Steel
Rigid or Flex Liner
Mantel or
Top Facing
Fig. # 3
SCREWS