Maintenance and Care
5.7.1 Changing the brushes
Check the brushes (Fig. 14/1) in the
brush head (Fig. 14/2) weekly for signs
of wear. In the case of wear to a brush
length of 1.5 cm, the brushes must be
changed.
Eject brush:
Raise the brush head using the lever
(Fig. 14/3). Press the button (Fig. 14/4)
for approx. 5 seconds when the brush
head is raised. Brush ejection is indica-
ted in the indicator field by four icons
which light up successively.
After brush ejection, the top and bottom
row of symbols flash alternately. The
machine is not ready to operate. Switch
the machine off using the main switch.
Attach brush:
Switch the machine on again using the
main switch. Position the brush cente-
red under the raised brush head. Lower
40
the brush head. When the brush head
drive is switched on by means of the
dead-man's switch of the bail system,
the brush is automatically attached.
5.7.2 Changing the deflector roller
Check the deflector roller (Fig. 14/5)
weekly and change it as necessary.
5.7.3 Changing the sealing strip
Check the sealing strip (Fig. 14/6) wee-
kly and change it as necessary. To do
this, loosen the fastening device and re-
move the sealing strip. Installation is
carried out in the reverse sequence.