GB
WARNING!
Rotating parts can cause injury, take great care.
WARNING!
There is a risk of tipping if the wire feed unit is fitted with a counterbalance arm. Secure the
equipment, especially if used on an uneven or sloping surface.
When moving the equipment use intended handle. NOTE! Never pull on the gun.
6.1

Connections and control devices

Connecting control cable
When connecting the control cable, it is
important to secure the cable with the
load--removing grommet.
Ensure that the cover is properly screwed
into place.
OrigoFeed 30- -4
1
Knob for setting wire feed
speed
2
Switch for activation of 2/4 stroke, spot
welding, cold wire feed or gas purging
3
Knob for setting spot welding time
4
Knob for setting burnback time
5
Switch for creep start OFF / ON
bm38d1ea
6
Connection for welding gun
7
Connection for welding current from power
source, (OKC)
8
Connection for shielding gas
9
Connection for control cable from power
source