AMX MVP-7500 Operation/Reference Manual page 90

7.5" & 8.4” modero viewpoint
Hide thumbs Also See for MVP-7500:
Table of Contents

Advertisement

Setup Pages
The elements of this page include:
Cache Settings/Cache Setup Page Elements
Back:
WiFi/Wired icon:
Connection Status icon:
Image Cache Settings:
Flash Cache Size
Flash/RAM Cache Expires
Enable:
Clear Cache:
Image Cache Status:
RAM Max Size
RAM Current Size
RAM Hit Rate
Items in Cache (RAM)
Flash Current Size
Flash Hit Rate
Items in Cache (Flash)
76
Saves all changes and returns to the previous page.
The icon to the left of the Connection Status Icon displays whether the current
connection to the Master is Wireless (image of a radio antenna) or Wired
(image of three networked computers).
The icon in the upper-right corner of each Setup page shows online/offline state
of the panel to the master.
• Bright red - disconnected
• Bright green - connected. Blinks when a blink message is received to dark
green every 5 seconds for half a second then go back to bright green.
• Bright yellow - panel missed a blink message from the master. It will remain
yellow for 3 missed blink messages and then turn red. It will return to green
when a blink message is received.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx
Master.
Allocates Flash memory for image caching.
Press the Up and Down arrows to add and remove memory. Flash memory
allocation cannot exceed the amount of Flash memory on the panel.
Press the Up and Down arrows to change the amount of time the images stay
in cache memory. The options are:
• Never
• 2 Hours
• 8 Hours
• 1 Day
• 2 Days
• 5 Days
Press this button to toggle the image Flash cache option On and Off.
Press this button to clear both the Flash and RAM cache of all stored images.
The status of the memory available versus in use.
The maximum amount of memory available for all image caching.
The memory that is currently in use for caching static and dynamic images.
The percentage of image requests (static and dynamic) satisfied by accessing
the cache.
100 * (# of cache hits) / (# of cache hits + # of cache misses)
# of cache hits - the number of times an image was requested that the image
was found in the cache. If your hit rate is low, you may want to consider
enabling Flash cache.
# of cache misses - the number of times an image was requested that the
image could not be found in the cache, and the image had to either be loaded
from flash or obtained via the network (for dynamic images). It is considered a
RAM Cache Miss even if the image is subsequently found in flash cache.
The number of images that are currently stored in the RAM cache.
The maximum flash space allocated for image caching. Flash space is used for
caching only when there is not enough available memory in the RAM cache for
a newly requested image (it is used only for dynamic images).
The percentage of image requests (dynamic only) that are satisfied by
accessing the flash cache.
100 * (# of flash cache hits) / (# of flash cache hits + # of flash cache misses)
# of flash cache hits - # of times a dynamic image could not be found in RAM
cache but was found in flash cache
# of flash cache misses - # of times a dynamic image could not be found in
either RAM or flash cache. RAM cache hits are not relevant in this calculation.
The number of images that are currently stored in the Flash cache.
MVP-7500/8400 Modero Viewpoint Wireless Touch Panels