It is the customer's responsibility:
To contact a quali ed electrical installer.
To assure that the electrical installation is adeq u ate and in conformance with National Electrical
code, ANSI/NFPA 70-latest edition, and all local co des and ordinances.
The outlet should be:
120 volt(112.8min. – 127.2 max.), min.15Ampere capacity
Protected by a 15Ampere fuse or circuit breaker
14 gauge copper wiring

2.2 TESTING THE UNIT

Carefully remove the unit from the packing box. Prior to installing the unit, test to make sure the
unit operates properly by plugging the unit's power cord into a conveniently located 120V grounded
outlet.
Caution:
!
Warning:
!
er to operating instructions regarding the various controls and features of the unit.
Ref
Metal screw
Cover of grounded
outlet box
Grounding pin
The unit's power cord must be connected to properly grounded
and protected 120V outlet. Please always use ground fault
protection where required by the electrical code.
Do not operate the unit if it is damaged or it has
malfunctioned. Please call the customer service telephone
number.