Chapter 4 — Troubleshoot and Maintain the SF61B
Replace the Battery of the SF61B
78
Integrated circuits on printed circuit boards (PCBs) in this
equipment are sensitive to damage by electrostatic discharge
(ESD). Prevent ESD by always wearing skin contact ground
straps firmly attached to the equipment metal base assembly
when working inside of the equipment housing. Failure to
comply may result in damage to PCB components.
To change the battery
1 Loosen the screw holding the battery cover.
2 Remove the battery cover.
3 Disconnect the battery cable and remove the battery.
4 Install the new battery
•
Plug in connector
•
Place connector side of battery gently against foam padding
Lower the battery in to place
•
5 Install the battery cover and tighten the screw (56 N cm/4.956 in-
lb).
SF61 Cordless Scanner User's Guide