Multi-Amp Systems Using 7000 Series Amplifiers; Safety First; Overview; Multi-Amp Configuration Accessories - AE Techron 7000-Series Configuration Manual

Multi-amp systems
Hide thumbs Also See for 7000-Series:
Table of Contents

Advertisement

7000-SERIES MULTI-AMP CONFIGURATION GUIDE

1 Multi-Amp Systems Using 7000 Series Amplifiers

1.1

Safety First

Throughout these instructions special emphasis is placed on good safety practices. The WARNING and
CAUTION graphics are used to highlight certain topics that require extra precaution.
1.2

Overview

A single 7000-Series amplifier can provide continuous output current or voltage only up to a certain level. If
you need increased output above those levels, you can combine multiple amplifiers into a system that can
provide increased voltage or current. Because the internal circuitry of a 7000-Series amplifier is not
connected to chassis ground, these
amplifiers are well suited for use in
series or parallel with other like-
model amplifiers within the Series.
Each 7000-Series amplifier added
to a Series multi-amp system will
increase the continuous voltage
output, while each amplifier added
to a Parallel multi-amp system will
increase the continuous current
output. See Figure 1.1 for the
approximate output levels you can
expect from each multi-amp system.
While it is possible to operate a
multi-amp system in either
Controlled Voltage or Controlled
Current modes of operation, multi-
amp operation in Controlled
Current mode requires additional
equipment configuration, and so is
beyond the scope of this Guide.
Please contact AE Techron Tech Support for assistance with configuring a multi-amp system for
Controlled Current operation.
For assistance in determining the best 7000-Series multi-amp configuration to meet your requirements,
please contact AE Techron.
This Guide will provide step-by-step instructions for setting up a Series or Parallel controlled-voltage multi-
amp system using AE Techron 7000-Series amplifiers.
1.3

Multi-Amp Configuration Accessories

The following accessories are available from AE Techron. They are recommended for use in the configuration
of 7000-Series multi-amp systems. For a listing of recommended accessories by multi-amp system type,
please refer to Section 1.4.
SIM-OPTOC – Specialized input card required for all Series configurations. Includes input card and BNC
connector safety cover.
4
Amplifier
Model
Configuration
Two amps in Series
Three amps in Series
7224
Two amps in Parallel
Three amps in Parallel
Four amps in Parallel
Two amps in Series
Three amps in Series
7548
Two amps in Parallel
Three amps in Parallel
Four amps in Parallel
Two amps in Series
Three amps in Series
7796
Two amps in Parallel
Three amps in Parallel
Four amps in Parallel
Figure 1.1 – Maximum Continuous Output in
7000-Series Multi-amp Systems
Information subject to change
Continuous Output
(100% Duty Cycle)
Up to 316 Vpk
Up to 474 Vpk
Up to 90 Apk
Up to 135 Apk
Up to 180 Apk
Up to 390 Vpk
Up to 585 Vpk
Up to 86 Apk
Up to 129 Apk
Up to 172 Apk
Up to 318 Vpk
Up to 477 Vpk
Up to 254 Apk
Up to 381 Apk
Up to 508 Apk
97-8002465_06-09-14