GEN750W models
Table 7-4:
Current programming range
Minimum
Model
GEN6-100
000.00
GEN8-90
00.00
GEN12.5-60
00.000
GEN20-38
00.000
GEN30-25
00.000
GEN40-19
00.000
GEN60-12.5
00.000
GEN80-9.5
0.000
GEN100-7.5
0.000
GEN150-5
0.000
GEN300-2.5
0.000
GEN600-1.3
0.000
NOTE:
The power supply can accept values higher by 5% than the table values, however it
is not recommended to program the power supply over the rated values.
Table 7-6: OVP programming range
Model
Rated Output Voltage (V)
6
8
12.5
20
30
40
50
60
80
100
150
300
600
7.7.7 Status control commands
Refer to section 7-8 for definition of the registers.
Command
#
Reads the complete power supply status.
1
STT?
Returns ASCII characters representing the following data, separated by commas:
MV<actual (measured) voltage>
PV<programmed (set) voltage>
MC<actual (measured) current>
Example response: MV(45.201),PV(45),MC(4.3257),PC(10),SR(30),FR(00)
2
FLT?
Reads Fault Conditional Register. Return 2-digit hex.
FENA
3
Set Fault Enable Register using 2-digit hex.
FENA?
4
Reads Fault Enable Register. Returns 2-digit hex.
Reads Fault Event Register. Returns 2-digit hex. Clears bits of Fault Event Register.
5
FEVE?
STAT?
Reads Status Conditional Register. Returns 2-digit hex.
6
SENA
Sets Status Enable Register using 2-digit hex.
7
SENA?
Reads Status Enable Register. Returns 2-digit hex.
8
Reads Status Event register. Returns 2-digit hex. Clears bits of Status Event register.
SEVE?
9
Maximum
(A)
(A)
100.00
90.00
60.000
38.000
25.000
19.000
12.500
9.500
7.500
5.000
2.500
1.300
Minimum
Maximum
(V)
(V)
7.50
0.5
10.0
0.5
15.0
1.0
24.0
1.0
36.0
2.0
44.0
2.0
57.0
5.0
66.0
5.0
88.0
5.0
110
5.0
165
5.0
330
5.0
660
5.0
GEN1500W models
Table 7-5:
Current programming range
Model
GEN6-200
GEN8-180
GEN12.5-120
GEN20-76
GEN30-50
GEN40-38
GEN50-30
GEN60-25
GEN80-19
GEN100-15
GEN150-10
GEN300-5
GEN600-2.6
Table 7-7: UVL programming range
Model
Rated Output Voltage (V)
6
8
12.5
20
30
40
50
60
80
100
150
300
600
Description
PC<programmed (set) current>
SR<status register, 2-digit hex>
FR<fault register, 2-digit hex>
56
56
Minimum
Maximum
(A)
(A)
200.00
000.00
180.00
000.00
120.00
000.00
76.00
00.00
50.000
00.000
38.000
00.000
30.000
00.000
25.000
00.000
19.000
00.000
00.000
15.000
00.000
10.000
0.000
5.000
0.000
2.600
Minimum
Maximum
(V)
(V)
5.70
0
7.60
0
11.9
0
19.0
0
28.5
0
38.0
0
47.5
0
57.0
0
76.0
0
95.0
0
142
0
285
0
570
0
Need help?