For the commands for PJLink™, see the table on the next page.
The control may not be performed correctly or the monitoring data may not be obtained correctly in the following conditions:
-
During standby
-
During zoom/focus adjustment
-
During lens shift adjustment
-
During input source switching
-
During auto position execution
-
During BLANK
-
During command processing
-
Before the splash screen disappears after the power is turned on.
During zoom/focus adjustment, lens shift adjustment, BLANK, etc., it may take approx. 5 seconds to receive a response to a
command.
Use 1 controller to control/monitor 1 projector.
For how to control/monitor using PJLink™, see the operation manual of the PJLink™ application you use.
When you monitor the projector's operating state using this function by issuing inquiry commands successively, issue an inquiry
command after receiving the response to the previous inquiry command from the projector.
Connection
When STANDBY MODE of the INSTALLATION 1 menu of the projector is set to LOW, the network function is disabled. To enable
the network function, set STANDBY MODE to STANDARD.
Configure the initial network settings first.
You can configure the initial settings using the projector menu.
PJLink™ supported commands
The table below shows commands to control the projector using the PJLink™ protocol.
Command
POWR
POWR?
INPT
INPT?
AVMT
AVMT?
ERST?
R5905597 PHXX SERIES 20/05/2014
Description
Power control
Inquiry about the power state
Input switching
Inquiry about input switching
Mute control
Inquiry about the mute state
Inquiry about the error state
Remark (Parameter)
0 = Standby
1 = Power on
0 = Standby
1 = Power on
2 = Cooling down
3 = Warming up
11 = COMPUTER1
12 = COMPUTER2
21 = VIDEO
22 = S-VIDEO
31 = HDMI
32 = DVI
33 = SDI (only PHWU-81B only)
30 = Video mute disable
31 = Video mute enable
1st byte: Fan error, 0 or 2
2nd byte: Lamp error, 0 to 2
3rd byte: Temperature error, 0 or 2
4th byte: Cover open error, 0 or 2
5th byte: Filter error, 0 or 2
6th byte: Other error, 0 or 2
0 to 2 mean as follows:
0 = No error detected, 1 = Warning, 2 = Error
9. Advanced features
89