Motherboard Jumper Information
The table below provides default jumper settings. This information is provided to
enable Sun service personnel to restore the default system jumper configuration. If
you are not a Sun service engineer, do not change jumper settings.
Note – Changing the setting for JP1 could cause damage to the server.
TABLE 2
Jumper ID
JP1
JP2
JP3
JP4
JP5
JP6
JP8
JP10
JP11
6
Sun Fire V210 and V240 Servers Product Notes • February 2004
Default Jumper settings
Default setting
1-2: Fitted
3-4: Fitted
5-6: Not Fitted
7-8: Not Fitted
9-10: Fitted
1-2: Not Fitted
1-2: Not Fitted
1-2: Fitted
3-4: Not Fitted
5-6: Not Fitted
7-8: Not Fitted
9-10: Not Fitted
1-2: Not Fitted
1-2: Fitted (this is non-
functional setting)
2-3: Not Fitted
1-2: Fitted
2-3: Not Fitted
1-2: Not Fitted
1-2: Not Fitted
Additional information
Processor core voltage. Do not alter this jumper
setting.
ALOM Flash ROM swap halves. Only service
personnel should modify this setting. Fitting a
jumper effects the swap.
ALOM reset. Used for testing the system only.
System configuration. Do not alter this jumper
setting.
ATAPI device master/slave. Do not alter this
jumper setting.
ROMBO enable. Only service personnel should
modify this setting. Fit jumper to 2-3 to enable
ROMBO.
Clear CMOS. Only service personnel should
modify this setting. Fit jumper to 2-3 to clear
CMOS.
Override PSON#. Only service personnel should
modify this setting.
ROM write-protect. Only service personnel should
modify this setting.