Hard Drives - Dell PowerEdge R630 Owner's Manual

Rack server
Hide thumbs Also See for PowerEdge R630:
Table of Contents

Advertisement

Figure 20. Installing the memory module
1.
memory module
3.
memory-module socket ejector (2)
When the memory module is properly seated in the socket, the levers on the memory module socket
align with the levers on the other sockets that have memory modules installed.
5.
Repeat steps 4 and 5 of this procedure to install the remaining memory modules.
Next steps
1.
Install the cooling shroud.
2.
Follow the procedure listed in
3.
Press <F2> to enter System Setup, and check the System Memory setting.
The system should have already changed the value to reflect the installed memory.
4.
If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat
step 4 through step 7 of this procedure, checking to ensure that the memory modules are firmly
seated in their sockets.
5.
Run the system memory test in the system diagnostics.

Hard drives

All hard drives connect to the system board through the hard-drive backplane. Hard drives are supplied in
hot-swappable hard-drive carriers that fit in the hard-drive slots.
CAUTION: Before attempting to remove or install a hard drive while the system is running, see the
documentation for the storage controller card to ensure that the host adapter is configured
correctly to support hot-swap hard drive removal and insertion.
CAUTION: Do not turn off or reboot your system while the hard drive is being formatted. Doing
so can cause a hard drive failure.