Readouts

U s a g e r e a d o u t s ( TIME)
Read the total number of power-on hours (
hours since last reset (
The resettable counters may be used to track overall usage and lamp life. To reset to zero, display the readout and then press
[↑] for 5 seconds.
D M X v a l u e r e a d o u t s ( dMXL)
Read the DMX start code (
is 0 and that the fixture is receiving the expected commands.
If the fixture is set to a DMX mode where some or all of the channels between 10 and 13 are not used, the readout on these
channels will be
N/A
S o f t w a r e v e r s i o n r e a d o u t s ( VER)
Read the version number of the CPU software (
(
dISP
). The CPU software version is also displayed for a moment at power up.
T e m p e r a t u r e r e a d o u t s ( SPEC/ TEMP)
Read temperature in the base (
tures above 100° C are shown as
The temperature sensors are calibrated at the factory and adjustment should not be necessary. The following procedure cali-
brates the sensors if they give no or faulty readings.
1.
Allow the unit to cool to room temperature (powered off for at least 4 hours).
2.
Measure the room temperature in Celsius. (To convert F° to C°, subtract 32° and then multiply by
0.555.)
3.
Power up the unit and allow it to reset.
4.
Press the [MENU] and [↓] keys at the same time and hold them for 3 seconds until "25" shows in the
display.
Press the [↑] and [↓] keys until the display shows the temperature measured.
5.
6.
Press [ENTER] to save the setting.

Manual control

M a n u a l c o n t r o l ( M AN)
The manual control menu permits you to do the following without a controller:
reset the fixture (
turn the lamp on and off (
open, close, and strobe the shutter at 3 speeds (
control the dimmer (
control the CMY wheels (
move the color wheel to each position (
control both beam shapers (
control pan and tilt (
Po H
), power-on hours since last reset (
RLAH
), total number of lamp strikes (
STCO
) and DMX values received for each channel. This is an easy way to check that the start code
. Note: the channel number is 1 less in the readout than it is in the DMX protocol.
) and head (
bASE
HEAd
+100
.
)
R ST
L ON
,
L oFF
)
dIM
)
CY AN, YEL , M AG
COL
)
)
BS1, BS2
P AN
,
TIL T
)
User Manual
LSTR
), and the number of lamp strikes since last reset (
CPU
), pan/tilt feedback circuit (
) in Celsius. Temperatures below 25° C are shown as
SH UT
)
)
RPoH
), total lamp hours (
LA H
FEbA
), and display module software
-25
), lamp
RLST
).
; tempera-